Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Updated to osm-network version 0.5 #1387

Merged
merged 5 commits into from
Nov 10, 2024
Merged
Show file tree
Hide file tree
Changes from 3 commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
5 changes: 3 additions & 2 deletions config/config.default.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -84,7 +84,7 @@ co2_budget:

# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#electricity
electricity:
voltages: [200., 220., 300., 380., 500., 750.]
voltages: [220., 300., 330., 380., 400., 500., 750.]
base_network: osm-prebuilt
osm-prebuilt-version: 0.4
gaslimit_enable: false
Expand Down Expand Up @@ -278,10 +278,11 @@ conventional:
# docs in https://pypsa-eur.readthedocs.io/en/latest/configuration.html#lines
lines:
types:
200.: "Al/St 240/40 2-bundle 200.0"
220.: "Al/St 240/40 2-bundle 220.0"
300.: "Al/St 240/40 3-bundle 300.0"
330.: "Al/St 240/40 3-bundle 300.0"
380.: "Al/St 240/40 4-bundle 380.0"
400.: "Al/St 240/40 4-bundle 380.0"
500.: "Al/St 240/40 4-bundle 380.0"
750.: "Al/St 560/50 4-bundle 750.0"
s_max_pu: 0.7
Expand Down
4 changes: 2 additions & 2 deletions doc/configtables/electricity.csv
Original file line number Diff line number Diff line change
@@ -1,7 +1,7 @@
,Unit,Values,Description
voltages,kV,"Any subset of {200., 220., 300., 380., 500., 750.}",Voltage levels to consider
voltages,kV,"Any subset of {220., 300., 330., 380., 400., 500., 750.}",Voltage levels to consider
base_network, --, "Any value in {'entsoegridkit', 'osm-prebuilt', 'osm-raw}", "Specify the underlying base network, i.e. GridKit (based on ENTSO-E web map extract, OpenStreetMap (OSM) prebuilt or raw (built from raw OSM data), takes longer."
osm-prebuilt-version, --, "float, any value in range 0.1-0.4", "Choose the version of the prebuilt OSM network. Defaults to latest Zenodo release."
osm-prebuilt-version, --, "float, any value in range 0.1-0.5", "Choose the version of the prebuilt OSM network. Defaults to latest Zenodo release."
gaslimit_enable,bool,true or false,Add an overall absolute gas limit configured in ``electricity: gaslimit``.
gaslimit,MWhth,float or false,Global gas usage limit
co2limit_enable,bool,true or false,Add an overall absolute carbon-dioxide emissions limit configured in ``electricity: co2limit`` in :mod:`prepare_network`. **Warning:** This option should currently only be used with electricity-only networks, not for sector-coupled networks..
Expand Down
8 changes: 4 additions & 4 deletions doc/data_sources.rst
Original file line number Diff line number Diff line change
Expand Up @@ -299,10 +299,10 @@ Data in this section is retrieved and extracted in rules specified in ``rules/re
``data/osm-prebuilt``

- **Source:** OpenStreetMap; Xiong, B., Neumann, F., & Brown, T. (2024).
Prebuilt Electricity Network for PyPSA-Eur based on OpenStreetMap Data (0.4)
[Data set]. Zenodo. https://doi.org/10.5281/zenodo.13759222
- **Link:** https://zenodo.org/records/13759222
- **License:** ODbL (`reference <https://zenodo.org/records/13759222>`)
Prebuilt Electricity Network for PyPSA-Eur based on OpenStreetMap Data (0.5)
[Data set]. Zenodo. https://doi.org/10.5281/zenodo.13981528
- **Link:** https://zenodo.org/records/13981528
- **License:** ODbL (`reference <https://zenodo.org/records/13981528>`)
- **Description:** Pre-built data of high-voltage transmission grid in Europe from OpenStreetMap.

``data/osm-raw``
Expand Down
3 changes: 3 additions & 0 deletions doc/release_notes.rst
Original file line number Diff line number Diff line change
Expand Up @@ -80,6 +80,9 @@ Upcoming Release

* Bugfix: Bug when multiple DC links are connected to the same DC bus and the DC bus is connected to an AC bus via converter. In this case, the DC links were wrongly simplified, completely dropping the shared DC bus. Bug fixed by adding preceding converter removal. Other functionalities are not impacted.

* Updated osm-prebuilt base network to version 0.5, for changelog, see https://zenodo.org/records/13981528


PyPSA-Eur 0.13.0 (13th September 2024)
======================================

Expand Down
1 change: 1 addition & 0 deletions rules/retrieve.smk
Original file line number Diff line number Diff line change
Expand Up @@ -545,6 +545,7 @@ if config["enable"]["retrieve"] and (
0.2: "13342577",
0.3: "13358976",
0.4: "13759222",
0.5: "13981528",
}

# update rule to use the correct version
Expand Down
Loading