Notifications
You must be signed in to change notification settings - Fork 2.1k
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Fix commissioning with a node ID we've used before to not reuse CASE sessions. #29418
Merged
mergify
merged 1 commit into
project-chip:master
from
bzbarsky-apple:fix-pairing-stale-node-id
Sep 22, 2023
Merged
Fix commissioning with a node ID we've used before to not reuse CASE sessions. #29418
mergify
merged 1 commit into
project-chip:master
from
bzbarsky-apple:fix-pairing-stale-node-id
Sep 22, 2023
Conversation
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
…sessions. This was coming up in some cert tests, where we commission a device, then factory reset it, then try to commission it again with the same node id. When we went to send CommissioningComplete for the second commissioning, we would try to reuse the existing CASE session (to the pre-reset device), which obviously failed. The fix is to just ensure we have no existing sessions to the relevant node id before we start CASE setup. Also adds a unit test for this case. This caught a bug in the test harness: factoryReset was clearing the KVS of running processes without restarting them, which is not how factory reset would normally work.
63e415b
to
5a34b79
Compare
saurabhst
approved these changes
Sep 22, 2023
cecille
approved these changes
Sep 22, 2023
andy31415
approved these changes
Sep 22, 2023
pidarped
approved these changes
Sep 22, 2023
PR #29418: Size comparison from 40a17dc to 5a34b79 Increases (3 builds for linux)
Decreases (1 build for telink)
Full report (66 builds for bl602, bl702, bl702l, cc13x4_26x4, cc32xx, cyw30739, efr32, esp32, k32w, linux, mbed, nrfconnect, psoc6, qpg, telink)
|
jmartinez-silabs
approved these changes
Sep 22, 2023
jtung-apple
approved these changes
Sep 22, 2023
HunsupJung
pushed a commit
to HunsupJung/connectedhomeip
that referenced
this pull request
Oct 23, 2023
…sessions. (project-chip#29418) This was coming up in some cert tests, where we commission a device, then factory reset it, then try to commission it again with the same node id. When we went to send CommissioningComplete for the second commissioning, we would try to reuse the existing CASE session (to the pre-reset device), which obviously failed. The fix is to just ensure we have no existing sessions to the relevant node id before we start CASE setup. Also adds a unit test for this case. This caught a bug in the test harness: factoryReset was clearing the KVS of running processes without restarting them, which is not how factory reset would normally work.
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
This was coming up in some cert tests, where we commission a device, then factory reset it, then try to commission it again with the same node id. When we went to send CommissioningComplete for the second commissioning, we would try to reuse the existing CASE session (to the pre-reset device), which obviously failed.
The fix is to just ensure we have no existing sessions to the relevant node id before we start CASE setup.
Also adds a unit test for this case. This caught a bug in the test harness: factoryReset was clearing the KVS of running processes without restarting them, which is not how factory reset would normally work.