add check of admin-power-state after disabling controller cards
  • Loading branch information
rszarecki authored Feb 28, 2025
1 parent d0dac61 commit 9ae9407
Showing 1 changed file with 4 additions and 3 deletions.
Original file line number Diff line number Diff line change
Expand Up @@ -49,10 +49,11 @@
* Select component with `redundant-role=PRIMARY`, store name as "previous_primary"
* Perfom Controller_Card switchover and then power down "previous_primary" component. Wait 5s.
* Collect `redundant-role` and `oper-status` from all components of CONTROLLER_CARD type as collected in test 1;
* verify that "previous_primary" controller `oper-status` is **not** `ACTIVE`;
* verify that "previous_primary" controller `oper-status` is **not** `ACTIVE` and/or its
`power-admin-state` is `POWER_DISABLED`;
* verify that at exectly one controller_card has `redundant-role=PRIMARY` and `oper-status=ACTIVE`
* Depending on implementation, above state may be not returned for "previous_primary" controller_card.
This satisfy condition of this controller's `oper-status` is **not** `ACTIVE`, and it's `redundant-rol`
* Depending on implementation, above leaves may be not returned for "previous_primary" controller_card.
This satisfy condition of this controller's `oper-status` is **not** `ACTIVE`, and it's `redundant-role`
is not `PRIMARY`
* if gNMI client can get this information, it is asumed controller card redundancy works.
More torough tests of failover are part of forwarding tests.