Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Code Quality - Improve variable naming #3115

Merged
merged 1 commit into from
Jul 21, 2024
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
82 changes: 47 additions & 35 deletions code/components/jomjol_flowcontroll/ClassFlowDefineTypes.h
Original file line number Diff line number Diff line change
Expand Up @@ -5,6 +5,10 @@

#include "ClassFlowImage.h"

/**
* Properties of one ROI
* FIXME: naming of members could use some refactoring to comply with common C++ coding style guidelines
*/
struct roi {
int posx, posy, deltax, deltay;
float result_float;
Expand All @@ -14,56 +18,64 @@ struct roi {
CImageBasis *image, *image_org;
};

/**
* FIXME: Why is this additional layer needed?
*/
struct general {
string name;
std::vector<roi*> ROI;
};

enum t_RateType {
AbsoluteChange,
RateChange
AbsoluteChange, // ignores the time difference; only the value difference is used comparison with NumberPost.maxRate
RateChange // time difference is considered and a normalized rate is used for comparison with NumberPost.maxRate
};


/**
* Holds all properties and settings of a sequence. A sequence is a set of digital and/or analog ROIs that are combined to
* provide one meter reading (value).
* FIXME: can be renamed to `Sequence`
*/
struct NumberPost {
float MaxRateValue;
bool useMaxRateValue;
t_RateType RateType;
bool ErrorMessage;
bool PreValueOkay;
bool AllowNegativeRates;
bool checkDigitIncreaseConsistency;
time_t lastvalue;
time_t timeStampTimeUTC;
string timeStamp;
double FlowRateAct; // m3 / min
double PreValue; // last value that was read out well
double Value; // last value read out, incl. corrections
string ReturnRateValue; // return value rate
string ReturnChangeAbsolute; // return value rate
string ReturnRawValue; // Raw value (with N & leading 0)
string ReturnValue; // corrected return value, if necessary with error message
string ReturnPreValue; // corrected return value without error message
string ErrorMessageText; // Error message for consistency check
int AnzahlAnalog;
int AnzahlDigital;
int DecimalShift;
int DecimalShiftInitial;
float AnalogDigitalTransitionStart; // When is the digit > x.1, i.e. when does it start to tilt?
int Nachkomma;
float MaxRateValue; // maxRate; upper bound for the difference between two consecutive readings; affected by maxRateType;
bool useMaxRateValue; // consistencyChecksEnabled; enables consistency checks; uses maxRate and maxRateType
t_RateType RateType; // maxRateType; affects how the value of maxRate is used for comparing the current and previous value
bool ErrorMessage; // FIXME: not used; can be removed
bool PreValueOkay; // previousValueValid; indicates that the reading of the previous round has no errors
bool AllowNegativeRates; // allowNegativeRate; defines if the consistency checks allow negative rates between consecutive meter readings.
bool checkDigitIncreaseConsistency; // extendedConsistencyCheck; performs an additional consistency check to avoid wrong readings
time_t lastvalue; // previousValueTimestamp; FIXME: usage in the code is ambigious, as sometimes it's `time_t` and sometimes `struct tm`
time_t timeStampTimeUTC; // FIXME: not used; can be removed.
string timeStamp; // localTimeStr; timestamp of last valid reading formatted as local time
double FlowRateAct; // currentRate; ΔValue/min; since usage is not limited to water meters, the physical unit is not known.
double PreValue; // lastValidValue; most recent value that could be read w/o any errors
double Value; // value; most recent readout; may include corrections
string ReturnRateValue; // currentRateStr; current normalized rate; ΔValue/min
string ReturnChangeAbsolute; // currentChangeStr; absolute difference between current and previous measurement
string ReturnRawValue; // rawValueStr; Raw value (with N & leading 0)
string ReturnValue; // valueStr; corrected return value, if necessary with error message
string ReturnPreValue; // lastValidValueStr; corrected return value without error message
string ErrorMessageText; // errorMessage; Error message for consistency checks
int AnzahlAnalog; // numAnalogRoi; number of analog ROIs used in this sequence
int AnzahlDigital; // numDigitalRoi; number of digital ROIs used in this sequence
int DecimalShift; // decimalShift; each increment shifts the decimal separator by one digit; value=value*10^decimalShift; pos. value shifts to the right
int DecimalShiftInitial; // decimalShiftInitial; same as decimalShift but is a const to reset decimalShift after calculations
float AnalogDigitalTransitionStart; // analogDigitalTransitionStartValue; FIXME: need a better description; When is the digit > x.1, i.e. when does it start to tilt?
int Nachkomma; // decimalPlaces; usually defined by the number of analog ROIs; affected by DecimalShift

string FieldV1; // Fieldname in InfluxDBv1
string MeasurementV1; // Measurement in InfluxDBv1
string FieldV1; // influxdbFieldName_v1; Name of the Field in InfluxDBv1
string MeasurementV1; // influxdbMeasurementName_v1; Name of the Measurement in InfluxDBv1

string FieldV2; // Fieldname in InfluxDBv2
string MeasurementV2; // Measurement in InfluxDBv2
string FieldV2; // influxdbFieldName_v2; Name of the Field in InfluxDBv2
string MeasurementV2; // influxdbMeasurementName_v2; Name of the Measurement in InfluxDBv2

bool isExtendedResolution;
bool isExtendedResolution; // extendResolution; Adds the decimal place of the least significant analog ROI to the value

general *digit_roi;
general *analog_roi;
general *digit_roi; // digitalRoi; set of digital ROIs for the sequence
general *analog_roi; // analogRoi; set of analog ROIs for the sequence

string name;
string name; // name; Designation for the sequence
};

#endif
Expand Down