Manual defrosting Setting #880

Closed
MichScha opened this issue Jan 1, 2023 · 2 comments
Closed

Manual defrosting Setting #880

MichScha opened this issue Jan 1, 2023 · 2 comments
Labels
enhancement New feature or request
Milestone

Comments

@MichScha
Copy link

MichScha commented Jan 1, 2023

RC300 / WLW196i

It is possible to set the manual defrosting mode to ON/OFF. In my system as it is completely in house it is not relevant and cannot be changed but the telegrams are still send out. Maybe this is interesting for someone - if not just close and ignore.

ON
000+00:37:45.502 N 3179: [emsesp] Thermostat(0x10) -W-> Boiler(0x08), ?(0x0291), data: 01
OFF
000+00:37:45.502 N 3179: [emsesp] Thermostat(0x10) -W-> Boiler(0x08), ?(0x0291), data: 00
@MichScha MichScha added the enhancement New feature or request label Jan 1, 2023
@proddy
Copy link
Contributor

proddy commented Jan 2, 2023

We could add this is a new thermostat command

MichaelDvP added a commit to MichaelDvP/EMS-ESP32 that referenced this issue Jan 2, 2023
@MichScha
Copy link
Author

MichScha commented Jan 2, 2023

Can be closed when PR is been merged - works!

@proddy proddy added this to the v3.5.0 milestone Jan 2, 2023
@MichScha MichScha closed this as completed Jan 5, 2023