I can take care of that. Can you please also provide screenshots from the Electrical Measurement cluster as well (make sure the attributes have been read)? Thanks! |
Thanks. Can you please apply a load on the plug and take another screenshot (1st one of the 2)? Since neither multipliers nor divisors are maintained, I need to know the active power to get the units right. |
here is the cature with a charge. |
Thanks again. How much power was it? I'd assume 96W? |
I ll try tomorrow the same test with a zwave plug from fibaro to give you the answer.
I plug my fruit juicer so 96w seem to be a good response.
Thanks for tour work see you tomorrow
Le 10 avr. 2020 à 20:46 +0200, SwoopX <notifications@github.com>, a écrit :
… Thanks again. How much power was it? I'd assume 96W?
—
You are receiving this because you authored the thread.
Reply to this email directly, view it on GitHub, or unsubscribe.
|
Cool. And don't forget to also make a screenshot of the basic cluster while the attributes have been read. Pretty sure I already know what's in there, but I wanna be on the safe side. |
Thanks! So in your last screenshot, the values already are as they should without any additional modification. Units are V, mA and W, great. However, the Current Summation does not seem to fit your last screenshot (from the app). Deconz is saying 61 (presumably Wh) and the app much more. Was the device reset recently? |
Hello
The device as been unplugged.
I don’t reset it, but i don’t use it too.
It was just plug for the test.
Best regards
Le 11 avr. 2020 à 20:55 +0200, SwoopX <notifications@github.com>, a écrit :
… Thanks! So in your last screenshot, the values already are as they should without any additional modification. Units are V, mA and W, great.
However, the Current Summation does not seem to fit your last screenshot (from the app). Deconz is saying 61 (presumably Wh) and the app much more. Was the device reset recently?
—
You are receiving this because you authored the thread.
Reply to this email directly, view it on GitHub, or unsubscribe.
|
Hi, do you know if its this model? |
@bilbon0bud I received today the same but when I bought it it was advertised as metered but they changed that now to no-metered (they removed that text). |
It seem to be metered, i m waiting the next release of deconz to test the
plugs.
the change made by swoopX seem to be merged, now i just have to wait a
little more.
Le lun. 11 mai 2020 à 17:24, vdbrink <notifications@github.com> a écrit :
… @bilbon0bud <https://github.com/bilbon0bud> I received today the same but
when I bought it it was advertised as metered but they changed that now to
no-metered (they removed that text).
Did you test if it's metered?
It doesn't send metered data over zigbee.
—
You are receiving this because you were mentioned.
Reply to this email directly, view it on GitHub
<#2677 (comment)>,
or unsubscribe
<https://github.com/notifications/unsubscribe-auth/AA7QDFNTHYTGNTAJHPPTPN3RRAKEPANCNFSM4MFOOL7Q>
.
|
It seems this issue is resolved or otherwise inactive. If it is not, please re-open! |
Hello
here is a smart plug zigbee from tuya, she have a power meter report, but i can't see him in deconz or in home assistant.
This device isn't inside the supported device list, so i give you some elements to integrate it in deconz.
Thanks for Your work.
Best Regards
The text was updated successfully, but these errors were encountered: