simplify script aggregates Corsica to Italy #152
Comments
So the solution would be to not aggregate links that cross countries? E.g.
|
I was thinking how to fix it as well, and that would fix it only by accident. We wouldn't want Corsica to be aggregated to France "Festland" as well if the link was from Corsica to France... right? Is that because it's an island, or an own synchronous zone? Or both? BTW, I think that there are more than this case were HVDC links are aggregated across country borders. simplify_links doesn't take countries & synchronous zones into account at all. Maybe that has to be added? |
Is it an option to specifically state the cases, where the simplification should not happen, e.g. an exception list? |
it would be definitely super easy to exclude this particular aggregation by removing the corresponding entry from the simplify_links_map. but doesn't fix all the other cases where we aggregate across country/synch-zone bounderies. I could check how many cases we're talking about here? |
I don't know if this helps, but I noticed looking at the bus region shapes that Corsica is always aggregated to mainland France (even for 256 clusters), whereas Sardinia always remains its own synchronous area and a separate region. Perhaps something is going wrong with the country shapes? |
@martacki do you have an overview if this is still the case or the issue can be closed? |
@martacki is this issue solved? |
Spatial management for solid biomass (transport)
Closed via #1215 |
full resolution includes one bus for corsica (bus "2306"), that, when simplifying, gets aggregated to Italy "Festland" (bus "2343") which we do not want to happen.
The bug is in the script "simplify_network.py", ie. happens in the step when going from elec.nc to elec_s.nc. The function where the bug happens is "simplify_links", where chains of links (HVDC lines) are aggregated to one representative link (HVDC line).
The text was updated successfully, but these errors were encountered: