14 changes: 13 additions & 1 deletion driver/fvGFS/atmosphere.F90
Original file line number Diff line number Diff line change
Expand Up @@ -509,7 +509,7 @@ subroutine atmosphere_init (Time_init, Time, Time_step, Grid_box, area)
! --- initiate the start for a restarted regional forecast
if ( Atm(mytile)%gridstruct%regional .and. Atm(mytile)%flagstruct%warm_start ) then

call start_regional_restart(Atm(1), &
call start_regional_restart(Atm(1), dt_atmos, &
isc, iec, jsc, jec, &
isd, ied, jsd, jed )
endif
Expand Down Expand Up @@ -1630,6 +1630,18 @@ subroutine atmosphere_state_update (Time, IPD_Data, IAU_Data, Atm_block, flip_vc

call nullify_domain()
call timing_on('FV_DIAG')

do k=1, Atm(n)%npz
do j=lbound(Atm(n)%pt,2),ubound(Atm(n)%pt,2)
do i=lbound(Atm(n)%pt,1),ubound(Atm(n)%pt,1)
if(Atm(n)%pt(i,j,k)>400.)then
Copy link
Collaborator

@junwang-noaa junwang-noaa Apr 3, 2020

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

This can be added later, but If we have bad Temperature >400, can we stop model from continue running (call mpp_error)?

Copy link
Collaborator

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

If you turn on the namelist "range_warn" the call to fv_diag will check the temperature for the data domain. An FMS "NOTE" will be emitted for temperatures outside the range of (150 - 350).

Copy link
Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Let's remove this block since I'm sure I put it there for debugging.

write(0,44351)i,j,k,Atm(n)%pt(i,j,k)
44351 format(' BAD T atmosphere_state_update before fv_diag pt(',i3,',',i3,',',i3,')=',e12.5)
endif
enddo
enddo
enddo

call fv_diag(Atm(mytile:mytile), zvir, fv_time, Atm(mytile)%flagstruct%print_freq)
first_diag = .false.
call timing_off('FV_DIAG')
Expand Down
5 changes: 5 additions & 0 deletions model/fv_arrays.F90
Original file line number Diff line number Diff line change
Expand Up @@ -985,6 +985,7 @@ module fv_arrays_mod
!< The default value is 4 (recommended); fourth-order interpolation
!< is used unless c2l_ord = 2.

integer :: nrows_blend = 0 !< # of blending rows in the outer integration domain.

real(kind=R_GRID) :: dx_const = 1000. !< Specifies the (uniform) grid-cell-width in the x-direction
!< on a doubly-periodic grid (grid_type = 4) in meters.
Expand All @@ -1006,6 +1007,10 @@ module fv_arrays_mod

integer :: bc_update_interval = 3 !< Default setting for interval (hours) between external regional BC data files.

logical :: regional_bcs_from_gsi = .false. !< Default setting for using DA-updated BC files.

logical :: write_restart_with_bcs = .false. !< Default setting for writing restart files with boundary rows.

!>Convenience pointers
integer, pointer :: grid_number

Expand Down
15 changes: 14 additions & 1 deletion model/fv_control.F90
Original file line number Diff line number Diff line change
Expand Up @@ -331,6 +331,9 @@ module fv_control_mod
logical, pointer :: nested, twowaynest
logical, pointer :: regional
integer, pointer :: bc_update_interval
integer, pointer :: nrows_blend
logical, pointer :: regional_bcs_from_gsi
logical, pointer :: write_restart_with_bcs
integer, pointer :: parent_tile, refinement, nestbctype, nestupdate, nsponge, ioffset, joffset
real, pointer :: s_weight, update_blend

Expand Down Expand Up @@ -670,7 +673,8 @@ subroutine run_setup(Atm, dt_atmos, grids_on_this_pe, p_split)
nested, twowaynest, parent_grid_num, parent_tile, nudge_qv, &
refinement, nestbctype, nestupdate, nsponge, s_weight, &
ioffset, joffset, check_negative, nudge_ic, halo_update_type, gfs_phil, agrid_vel_rst, &
do_uni_zfull, adj_mass_vmr, fac_n_spl, fhouri, regional, bc_update_interval
do_uni_zfull, adj_mass_vmr, fac_n_spl, fhouri, regional, bc_update_interval, &
regional_bcs_from_gsi, write_restart_with_bcs, nrows_blend

namelist /test_case_nml/test_case, bubble_do, alpha, nsolitons, soliton_Umax, soliton_size
#ifdef MULTI_GASES
Expand Down Expand Up @@ -892,6 +896,12 @@ subroutine run_setup(Atm, dt_atmos, grids_on_this_pe, p_split)
Atm(n)%neststruct%refinement = -1
end if

if (Atm(n)%flagstruct%regional) then
if ( consv_te > 0.) then
call mpp_error(FATAL, 'The global energy fixer cannot be used on a regional grid. consv_te must be set to 0.')
end if
end if

if (Atm(n)%neststruct%nested) then
if (Atm(n)%flagstruct%grid_type >= 4 .and. Atm(n)%parent_grid%flagstruct%grid_type >= 4) then
Atm(n)%flagstruct%dx_const = Atm(n)%parent_grid%flagstruct%dx_const / real(Atm(n)%neststruct%refinement)
Expand Down Expand Up @@ -1233,6 +1243,9 @@ subroutine setup_pointers(Atm)
target_lon => Atm%flagstruct%target_lon
regional => Atm%flagstruct%regional
bc_update_interval => Atm%flagstruct%bc_update_interval
nrows_blend => Atm%flagstruct%nrows_blend
regional_bcs_from_gsi => Atm%flagstruct%regional_bcs_from_gsi
write_restart_with_bcs => Atm%flagstruct%write_restart_with_bcs
reset_eta => Atm%flagstruct%reset_eta
p_fac => Atm%flagstruct%p_fac
a_imp => Atm%flagstruct%a_imp
Expand Down