[NDM] Add cyberpower-pdu profile #15158

Merged
merged 3 commits into from
Aug 3, 2023
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
375 changes: 375 additions & 0 deletions snmp/datadog_checks/snmp/data/default_profiles/cyberpower-pdu.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,375 @@
extends:
- _base.yaml

sysobjectid: 1.3.6.1.4.1.3808.1.1.*

metadata:
device:
fields:
vendor:
value: "cyberpower"

metrics:
- MIB: CPS-MIB
table:
OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1
name: ePDULoadStatusTable
symbols:
- OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.2
name: cyberpower.ePDULoadStatusLoad
- OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.6
name: cyberpower.ePDULoadStatusVoltage
- OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.7
name: cyberpower.ePDULoadStatusActivePower
- OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.8
name: cyberpower.ePDULoadStatusApparentPower
- OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.9
name: cyberpower.ePDULoadStatusPowerFactor
metric_tags:
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.1
name: ePDULoadStatusIndex
tag: e_pdu_load_status_index
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.3
name: ePDULoadStatusLoadState
tag: e_pdu_load_status_load_state
mapping:
1: load_normal
2: load_low
3: load_near_overload
4: load_overload
- MIB: CPS-MIB
table:
OID: 1.3.6.1.4.1.3808.1.1.3.2.4.1
name: ePDULoadBankConfigTable
symbols:
- name: cyberpower.ePDULoadBankConfig
constant_value_one: true
metric_tags:
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.2.4.1.1.1
name: ePDULoadBankConfigIndex
tag: e_pdu_load_bank_config_index
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.2.4.1.1.5
name: ePDULoadBankConfigAlarm
tag: e_pdu_load_bank_config_alarm
mapping:
1: no_load_alarm
2: under_current_alarm
3: near_over_current_alarm
4: over_current_alarm
- MIB: CPS-MIB
table:
OID: 1.3.6.1.4.1.3808.1.1.3.3.5.1
name: ePDUOutletStatusTable
symbols:
- OID: 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.7
name: cyberpower.ePDUOutletStatusLoad
- OID: 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.8
name: cyberpower.ePDUOutletStatusActivePower
metric_tags:
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.1
name: ePDUOutletStatusIndex
tag: e_pdu_outlet_status_index
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.2
name: ePDUOutletStatusOutletName
tag: e_pdu_outlet_status_outlet_name
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.4
name: ePDUOutletStatusOutletState
tag: e_pdu_outlet_status_outlet_state
mapping:
1: outlet_status_on
2: outlet_status_off
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.9
name: ePDUOutletStatusAlarm
tag: e_pdu_outlet_status_alarm
mapping:
1: no_load_alarm
2: under_current_alarm
3: near_over_current_alarm
4: over_current_alarm
# - MIB: CPS-MIB # All three metric tags are scalar metrics with enums. Not supported yet.
# table:
# OID: 1.3.6.1.4.1.3808.1.1.3.3.6.1
# name: ePDUOutletBankTable
# symbols:
# - name: ePDUOutletBank
# constant_value_one: true
# metric_tags:
# - column:
# OID:
# name: ePDUOutletBankIndex
# - column:
# OID: 1.3.6.1.4.1.3808.1.1.3.4.1.1
# name: ePDUPowerSupply1Status
# tag: e_pdu_power_supply1_status
# mapping:
# 1: power_supply_one_ok
# 2: power_supply_one_failed
# - column:
# OID: 1.3.6.1.4.1.3808.1.1.3.4.1.2
# name: ePDUPowerSupply2Status
# tag: e_pdu_power_supply2_status
# mapping:
# 1: power_supply_two_ok
# 2: power_supply_two_failed
# 3: power_supply_two_not_present
# - column:
# OID: 1.3.6.1.4.1.3808.1.1.3.4.1.3
# name: ePDUPowerSupplyAlarm
# tag: e_pdu_power_supply_alarm
# mapping:
# 1: all_available_power_supplies_ok
# 2: power_supply_one_failed
# 3: power_supply_two_failed
# 4: power_supply_oneand_two_failed
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I'm unclear on what makes the commented-out block above different from the block below - why do we have to exclude the outlet bank table but not the status bank table?

Copy link
Member Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Oh right, this comment seems wrong.
I don't remember the details that might be a mistake indeed

- MIB: CPS-MIB
table:
OID: 1.3.6.1.4.1.3808.1.1.3.5.2
name: ePDUStatusBankTable
symbols:
- name: cyberpower.ePDUStatusBank
constant_value_one: true
metric_tags:
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.5.2.1.1
name: ePDUStatusBankIndex
tag: e_pdu_status_bank_index
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.5.2.1.2
name: ePDUStatusBankNumber
tag: e_pdu_status_bank_number
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.5.2.1.3
name: ePDUStatusBankState
tag: e_pdu_status_bank_state
mapping:
1: bank_load_normal
2: bank_load_low
3: bank_load_near_overload
4: bank_load_overload
- MIB: CPS-MIB
table:
OID: 1.3.6.1.4.1.3808.1.1.3.5.4
name: ePDUStatusPhaseTable
symbols:
- name: cyberpower.ePDUStatusPhase
constant_value_one: true
metric_tags:
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.5.4.1.1
name: ePDUStatusPhaseIndex
tag: e_pdu_status_phase_index
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.5.4.1.2
name: ePDUStatusPhaseNumber
tag: e_pdu_status_phase_number
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.5.4.1.3
name: ePDUStatusPhaseState
tag: e_pdu_status_phase_state
mapping:
1: phase_load_normal
2: phase_load_low
3: phase_load_near_overload
4: phase_load_overload
- MIB: CPS-MIB
table:
OID: 1.3.6.1.4.1.3808.1.1.3.5.6
name: ePDUStatusOutletTable
symbols:
- name: cyberpower.ePDUStatusOutlet
constant_value_one: true
metric_tags:
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.5.6.1.1
name: ePDUStatusOutletIndex
tag: e_pdu_status_outlet_index
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.5.6.1.2
name: ePDUStatusOutletNumber
tag: e_pdu_status_outlet_number
- column:
OID: 1.3.6.1.4.1.3808.1.1.3.5.6.1.3
name: ePDUStatusOutletState
tag: e_pdu_status_outlet_state
mapping:
1: outlet_load_normal
2: outlet_load_low
3: outlet_load_near_overload
4: outlet_load_overload
- MIB: CPS-MIB
symbol:
OID: 1.3.6.1.4.1.3808.1.1.3.5.7
name: cyberpower.ePDUStatusInputVoltage
- MIB: CPS-MIB
symbol:
OID: 1.3.6.1.4.1.3808.1.1.3.5.8
name: cyberpower.ePDUStatusInputFrequency
- MIB: CPS-MIB
table:
OID: 1.3.6.1.4.1.3808.1.1.6.3.4
name: ePDU2DeviceStatusTable
symbols:
- OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.5
name: cyberpower.ePDU2DeviceStatusLoad
- OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.6
name: cyberpower.ePDU2DeviceStatusPeakLoad
- OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.15
name: cyberpower.ePDU2DeviceStatusApparentPower
- OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.16
name: cyberpower.ePDU2DeviceStatusPowerFactor
metric_tags:
- column:
OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.1
name: ePDU2DeviceStatusIndex
tag: e_pdu2_device_status_index
- column:
OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.3
name: ePDU2DeviceStatusName
tag: e_pdu2_device_status_name
- column:
OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.17
name: ePDU2DeviceStatusRoleType
tag: e_pdu2_device_status_role_type
mapping:
1: standalone
2: host
3: slave
- column:
OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.4
name: ePDU2DeviceStatusLoadState
tag: e_pdu2_device_status_load_state
mapping:
1: no_load_alarm
2: under_current_alarm
3: near_over_current_alarm
4: over_current_alarm
- column:
OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.12
name: ePDU2DeviceStatusPowerSupplyAlarm
tag: e_pdu2_device_status_power_supply_alarm
mapping:
1: normal
2: alarm
- column:
OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.13
name: ePDU2DeviceStatusPowerSupply1Status
tag: e_pdu2_device_status_power_supply1_status
mapping:
1: normal
2: alarm
- column:
OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.14
name: ePDU2DeviceStatusPowerSupply2Status
tag: e_pdu2_device_status_power_supply2_status
mapping:
1: normal
2: alarm
- MIB: CPS-MIB
table:
OID: 1.3.6.1.4.1.3808.1.1.6.4.4
name: ePDU2PhaseStatusTable
symbols:
- OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.5
name: cyberpower.ePDU2PhaseStatusLoad
- OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.6
name: cyberpower.ePDU2PhaseStatusVoltage
- OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.7
name: cyberpower.ePDU2PhaseStatusPower
- OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.8
name: cyberpower.ePDU2PhaseStatusApparentPower
- OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.9
name: cyberpower.ePDU2PhaseStatusPowerFactor
- OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.10
name: cyberpower.ePDU2PhaseStatusPeakLoad
metric_tags:
- column:
OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.1
name: ePDU2PhaseStatusIndex
tag: e_pdu2_phase_status_index
- column:
OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.4
name: ePDU2PhaseStatusLoadState
tag: e_pdu2_phase_status_load_state
mapping:
1: low_load
2: normal
3: near_overload
4: overload
- MIB: CPS-MIB
table:
OID: 1.3.6.1.4.1.3808.1.1.6.5.4
name: ePDU2BankStatusTable
symbols:
- OID: 1.3.6.1.4.1.3808.1.1.6.5.4.1.5
name: cyberpower.ePDU2BankStatusLoad
- OID: 1.3.6.1.4.1.3808.1.1.6.5.4.1.6
name: cyberpower.ePDU2BankStatusPeakLoad
metric_tags:
- column:
OID: 1.3.6.1.4.1.3808.1.1.6.5.4.1.1
name: ePDU2BankStatusIndex
tag: e_pdu2_bank_status_index
- column:
OID: 1.3.6.1.4.1.3808.1.1.6.5.4.1.4
name: ePDU2BankStatusLoadState
tag: e_pdu2_bank_status_load_state
mapping:
1: low_load
2: normal
3: near_overload
4: overload
- MIB: CPS-MIB
table:
OID: 1.3.6.1.4.1.3808.1.1.6.6.1.4
name: ePDU2OutletSwitchedStatusTable
symbols:
- name: cyberpower.ePDU2OutletSwitchedStatus
constant_value_one: true
metric_tags:
- column:
OID: 1.3.6.1.4.1.3808.1.1.6.6.1.4.1.1
name: ePDU2OutletSwitchedStatusIndex
tag: e_pdu2_outlet_switched_status_index
- column:
OID: 1.3.6.1.4.1.3808.1.1.6.6.1.4.1.4
name: ePDU2OutletSwitchedStatusName
tag: e_pdu2_outlet_switched_status_name
- column:
OID: 1.3.6.1.4.1.3808.1.1.6.6.1.4.1.5
name: ePDU2OutletSwitchedStatusState
tag: e_pdu2_outlet_switched_status_state
mapping:
1: outlet_status_on
2: outlet_status_off
- MIB: CPS-MIB
symbol:
OID: 1.3.6.1.4.1.3808.1.1.4.2.1.0
name: cyberpower.envir_temperature
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Out of curiosity, is there a reason we expose the fahrenheit but not the celsius? Does our UI handle unit switching?

Copy link
Member Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Good call out, our UI can handle the unit switching but only if the metadata csv is configured with the right unit or if the user configures it. Otherwise the value is shown without transformation.

It could make sense to submit only the celsius one, or both the celsius + the fahrenheit one.

- MIB: CPS-MIB
symbol:
OID: 1.3.6.1.4.1.3808.1.1.4.3.1.0
name: cyberpower.envirHumidity
metric_tags:
- OID: 1.3.6.1.4.1.3808.1.1.3.1.1.0
symbol: ePDUIdentName
tag: e_pdu_ident_name
- tag: e_pdu_ident_model_number
OID: 1.3.6.1.4.1.3808.1.1.3.1.5.0
symbol: ePDUIdentModelNumber
- tag: e_pdu_ident_serial_number
OID: 1.3.6.1.4.1.3808.1.1.3.1.6.0
symbol: ePDUIdentSerialNumber
- OID: 1.3.6.1.4.1.3808.1.1.4.1.1.0
symbol: envirIdentName
tag: envir_ident_name
- OID: 1.3.6.1.4.1.3808.1.1.4.1.2.0
symbol: envirIdentLocation
tag: envir_ident_location