snmp/datadog_checks/snmp/data/default_profiles/cyberpower-pdu.yaml
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,373 @@ | ||
extends: | ||
- _base.yaml | ||
|
||
sysobjectid: 1.3.6.1.4.1.3808.1.1.* | ||
|
||
metadata: | ||
device: | ||
fields: | ||
vendor: | ||
value: "cyberpower" | ||
|
||
metrics: | ||
- MIB: CPS-MIB | ||
table: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1 | ||
name: ePDULoadStatusTable | ||
symbols: | ||
- OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.2 | ||
name: ePDULoadStatusLoad | ||
- OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.6 | ||
name: ePDULoadStatusVoltage | ||
- OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.7 | ||
name: ePDULoadStatusActivePower | ||
- OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.8 | ||
name: ePDULoadStatusApparentPower | ||
- OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.9 | ||
name: ePDULoadStatusPowerFactor | ||
metric_tags: | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.1 | ||
name: ePDULoadStatusIndex | ||
tag: e_pdu_load_status_index | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.2.3.1.1.3 | ||
name: ePDULoadStatusLoadState | ||
tag: e_pdu_load_status_load_state | ||
mapping: | ||
1: load_normal | ||
2: load_low | ||
3: load_near_overload | ||
4: load_overload | ||
- MIB: CPS-MIB | ||
table: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.2.4.1 | ||
name: ePDULoadBankConfigTable | ||
symbols: | ||
- name: ePDULoadBankConfig | ||
constant_value_one: true | ||
metric_tags: | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.2.4.1.1.1 | ||
name: ePDULoadBankConfigIndex | ||
tag: e_pdu_load_bank_config_index | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.2.4.1.1.5 | ||
name: ePDULoadBankConfigAlarm | ||
tag: e_pdu_load_bank_config_alarm | ||
mapping: | ||
1: no_load_alarm | ||
2: under_current_alarm | ||
3: near_over_current_alarm | ||
4: over_current_alarm | ||
- MIB: CPS-MIB | ||
table: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.3.5.1 | ||
name: ePDUOutletStatusTable | ||
symbols: | ||
- OID: 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.7 | ||
name: ePDUOutletStatusLoad | ||
- OID: 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.8 | ||
name: ePDUOutletStatusActivePower | ||
metric_tags: | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.1 | ||
name: ePDUOutletStatusIndex | ||
tag: e_pdu_outlet_status_index | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.2 | ||
name: ePDUOutletStatusOutletName | ||
tag: e_pdu_outlet_status_outlet_name | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.4 | ||
name: ePDUOutletStatusOutletState | ||
tag: e_pdu_outlet_status_outlet_state | ||
mapping: | ||
1: outlet_status_on | ||
2: outlet_status_off | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.3.5.1.1.9 | ||
name: ePDUOutletStatusAlarm | ||
tag: e_pdu_outlet_status_alarm | ||
mapping: | ||
1: no_load_alarm | ||
2: under_current_alarm | ||
3: near_over_current_alarm | ||
4: over_current_alarm | ||
# - MIB: CPS-MIB # All three metric tags are scalar metrics with enums. Not supported yet. | ||
# table: | ||
# OID: 1.3.6.1.4.1.3808.1.1.3.3.6.1 | ||
# name: ePDUOutletBankTable | ||
# symbols: | ||
# - name: ePDUOutletBank | ||
# constant_value_one: true | ||
# metric_tags: | ||
# - column: | ||
# OID: | ||
# name: ePDUOutletBankIndex | ||
# - column: | ||
# OID: 1.3.6.1.4.1.3808.1.1.3.4.1.1 | ||
# name: ePDUPowerSupply1Status | ||
# tag: e_pdu_power_supply1_status | ||
# mapping: | ||
# 1: power_supply_one_ok | ||
# 2: power_supply_one_failed | ||
# - column: | ||
# OID: 1.3.6.1.4.1.3808.1.1.3.4.1.2 | ||
# name: ePDUPowerSupply2Status | ||
# tag: e_pdu_power_supply2_status | ||
# mapping: | ||
# 1: power_supply_two_ok | ||
# 2: power_supply_two_failed | ||
# 3: power_supply_two_not_present | ||
# - column: | ||
# OID: 1.3.6.1.4.1.3808.1.1.3.4.1.3 | ||
# name: ePDUPowerSupplyAlarm | ||
# tag: e_pdu_power_supply_alarm | ||
# mapping: | ||
# 1: all_available_power_supplies_ok | ||
# 2: power_supply_one_failed | ||
# 3: power_supply_two_failed | ||
# 4: power_supply_oneand_two_failed | ||
- MIB: CPS-MIB | ||
table: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.5.2 | ||
name: ePDUStatusBankTable | ||
symbols: | ||
- name: ePDUStatusBank | ||
constant_value_one: true | ||
metric_tags: | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.5.2.1.1 | ||
name: ePDUStatusBankIndex | ||
tag: e_pdu_status_bank_index | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.5.2.1.2 | ||
name: ePDUStatusBankNumber | ||
tag: e_pdu_status_bank_number | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.5.2.1.3 | ||
name: ePDUStatusBankState | ||
tag: e_pdu_status_bank_state | ||
mapping: | ||
1: bank_load_normal | ||
2: bank_load_low | ||
3: bank_load_near_overload | ||
4: bank_load_overload | ||
- MIB: CPS-MIB | ||
table: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.5.4 | ||
name: ePDUStatusPhaseTable | ||
symbols: | ||
- name: ePDUStatusPhase | ||
constant_value_one: true | ||
metric_tags: | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.5.4.1.1 | ||
name: ePDUStatusPhaseIndex | ||
tag: e_pdu_status_phase_index | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.5.4.1.2 | ||
name: ePDUStatusPhaseNumber | ||
tag: e_pdu_status_phase_number | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.5.4.1.3 | ||
name: ePDUStatusPhaseState | ||
tag: e_pdu_status_phase_state | ||
mapping: | ||
1: phase_load_normal | ||
2: phase_load_low | ||
3: phase_load_near_overload | ||
4: phase_load_overload | ||
- MIB: CPS-MIB | ||
table: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.5.6 | ||
name: ePDUStatusOutletTable | ||
symbols: | ||
- name: ePDUStatusOutlet | ||
constant_value_one: true | ||
metric_tags: | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.5.6.1.1 | ||
name: ePDUStatusOutletIndex | ||
tag: e_pdu_status_outlet_index | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.5.6.1.2 | ||
name: ePDUStatusOutletNumber | ||
tag: e_pdu_status_outlet_number | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.5.6.1.3 | ||
name: ePDUStatusOutletState | ||
tag: e_pdu_status_outlet_state | ||
mapping: | ||
1: outlet_load_normal | ||
2: outlet_load_low | ||
3: outlet_load_near_overload | ||
4: outlet_load_overload | ||
- MIB: CPS-MIB | ||
symbol: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.5.7 | ||
name: ePDUStatusInputVoltage | ||
- MIB: CPS-MIB | ||
symbol: | ||
OID: 1.3.6.1.4.1.3808.1.1.3.5.8 | ||
name: ePDUStatusInputFrequency | ||
- MIB: CPS-MIB | ||
table: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.3.4 | ||
name: ePDU2DeviceStatusTable | ||
symbols: | ||
- OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.5 | ||
name: ePDU2DeviceStatusLoad | ||
- OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.6 | ||
name: ePDU2DeviceStatusPeakLoad | ||
- OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.15 | ||
name: ePDU2DeviceStatusApparentPower | ||
- OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.16 | ||
name: ePDU2DeviceStatusPowerFactor | ||
metric_tags: | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.1 | ||
name: ePDU2DeviceStatusIndex | ||
tag: e_pdu2_device_status_index | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.3 | ||
name: ePDU2DeviceStatusName | ||
tag: e_pdu2_device_status_name | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.17 | ||
name: ePDU2DeviceStatusRoleType | ||
tag: e_pdu2_device_status_role_type | ||
mapping: | ||
1: standalone | ||
2: host | ||
3: slave | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.4 | ||
name: ePDU2DeviceStatusLoadState | ||
tag: e_pdu2_device_status_load_state | ||
mapping: | ||
1: no_load_alarm | ||
2: under_current_alarm | ||
3: near_over_current_alarm | ||
4: over_current_alarm | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.12 | ||
name: ePDU2DeviceStatusPowerSupplyAlarm | ||
tag: e_pdu2_device_status_power_supply_alarm | ||
mapping: | ||
1: normal | ||
2: alarm | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.13 | ||
name: ePDU2DeviceStatusPowerSupply1Status | ||
tag: e_pdu2_device_status_power_supply1_status | ||
mapping: | ||
1: normal | ||
2: alarm | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.3.4.1.14 | ||
name: ePDU2DeviceStatusPowerSupply2Status | ||
tag: e_pdu2_device_status_power_supply2_status | ||
mapping: | ||
1: normal | ||
2: alarm | ||
- MIB: CPS-MIB | ||
table: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.4.4 | ||
name: ePDU2PhaseStatusTable | ||
symbols: | ||
- OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.5 | ||
name: ePDU2PhaseStatusLoad | ||
- OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.6 | ||
name: ePDU2PhaseStatusVoltage | ||
- OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.7 | ||
name: ePDU2PhaseStatusPower | ||
- OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.8 | ||
name: ePDU2PhaseStatusApparentPower | ||
- OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.9 | ||
name: ePDU2PhaseStatusPowerFactor | ||
- OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.10 | ||
name: ePDU2PhaseStatusPeakLoad | ||
metric_tags: | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.1 | ||
name: ePDU2PhaseStatusIndex | ||
tag: e_pdu2_phase_status_index | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.4.4.1.4 | ||
name: ePDU2PhaseStatusLoadState | ||
tag: e_pdu2_phase_status_load_state | ||
mapping: | ||
1: low_load | ||
2: normal | ||
3: near_overload | ||
4: overload | ||
- MIB: CPS-MIB | ||
table: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.5.4 | ||
name: ePDU2BankStatusTable | ||
symbols: | ||
- OID: 1.3.6.1.4.1.3808.1.1.6.5.4.1.5 | ||
name: ePDU2BankStatusLoad | ||
- OID: 1.3.6.1.4.1.3808.1.1.6.5.4.1.6 | ||
name: ePDU2BankStatusPeakLoad | ||
metric_tags: | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.5.4.1.1 | ||
name: ePDU2BankStatusIndex | ||
tag: e_pdu2_bank_status_index | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.5.4.1.4 | ||
name: ePDU2BankStatusLoadState | ||
tag: e_pdu2_bank_status_load_state | ||
mapping: | ||
1: low_load | ||
2: normal | ||
3: near_overload | ||
4: overload | ||
- MIB: CPS-MIB | ||
table: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.6.1.4 | ||
name: ePDU2OutletSwitchedStatusTable | ||
symbols: | ||
- name: ePDU2OutletSwitchedStatus | ||
constant_value_one: true | ||
metric_tags: | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.6.1.4.1.1 | ||
name: ePDU2OutletSwitchedStatusIndex | ||
tag: e_pdu2_outlet_switched_status_index | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.6.1.4.1.4 | ||
name: ePDU2OutletSwitchedStatusName | ||
tag: e_pdu2_outlet_switched_status_name | ||
- column: | ||
OID: 1.3.6.1.4.1.3808.1.1.6.6.1.4.1.5 | ||
name: ePDU2OutletSwitchedStatusState | ||
tag: e_pdu2_outlet_switched_status_state | ||
mapping: | ||
1: outlet_status_on | ||
2: outlet_status_off | ||
metric_tags: | ||
- OID: 1.3.6.1.4.1.3808.1.1.3.1.1.0 | ||
symbol: ePDUIdentName | ||
tag: e_pdu_ident_name | ||
- tag: e_pdu_ident_model_number | ||
OID: 1.3.6.1.4.1.3808.1.1.3.1.5.0 | ||
symbol: ePDUIdentModelNumber | ||
- tag: e_pdu_ident_serial_number | ||
OID: 1.3.6.1.4.1.3808.1.1.3.1.6.0 | ||
symbol: ePDUIdentSerialNumber | ||
- OID: 1.3.6.1.4.1.3808.1.1.4.1.1.0 | ||
symbol: envirIdentName | ||
tag: envir_ident_name | ||
- OID: 1.3.6.1.4.1.3808.1.1.4.1.2.0 | ||
symbol: envirIdentLocation | ||
tag: envir_ident_location | ||
- OID: 1.3.6.1.4.1.3808.1.1.4.2.1.0 | ||
symbol: envirTemperature | ||
tag: envir_temperature | ||
- OID: 1.3.6.1.4.1.3808.1.1.4.3.1.0 | ||
symbol: envirHumidity | ||
tag: envir_humidity |