Notifications
You must be signed in to change notification settings - Fork 762
/
Copy pathcable_outlet.py
162 lines (144 loc) · 4.69 KB
/
cable_outlet.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
"""Module for Legrand Cable Outlet (with pilot wire functionality)."""
from zigpy.profiles import zgp, zha
from zigpy.quirks import CustomCluster, CustomDevice
import zigpy.types as t
from zigpy.zcl.clusters.general import (
Basic,
GreenPowerProxy,
Groups,
Identify,
OnOff,
Ota,
Scenes,
)
from zigpy.zcl.clusters.homeautomation import ElectricalMeasurement
from zigpy.zcl.foundation import (
BaseAttributeDefs,
BaseCommandDefs,
Direction,
ZCLAttributeDef,
ZCLCommandDef,
)
from zhaquirks.const import (
DEVICE_TYPE,
ENDPOINTS,
INPUT_CLUSTERS,
MODELS_INFO,
OUTPUT_CLUSTERS,
PROFILE_ID,
)
from zhaquirks.legrand import LEGRAND, MANUFACTURER_SPECIFIC_CLUSTER_ID
MANUFACTURER_SPECIFIC_CLUSTER_ID_2 = 0xFC40 # 64576
class DeviceMode(t.enum16):
PILOT_OFF = 0x0100
PILOT_ON = 0x0200
class LegrandCluster(CustomCluster):
"""LegrandCluster."""
cluster_id = MANUFACTURER_SPECIFIC_CLUSTER_ID
name = "LegrandCluster"
ep_attribute = "legrand_cluster"
class AttributeDefs(BaseAttributeDefs):
device_mode = ZCLAttributeDef(
id=0x0000,
type=t.data16, # DeviceMode
is_manufacturer_specific=True,
)
led_dark = ZCLAttributeDef(
id=0x0001,
type=t.Bool,
is_manufacturer_specific=True,
)
led_on = ZCLAttributeDef(
id=0x0002,
type=t.Bool,
is_manufacturer_specific=True,
)
class PilotWireMode(t.enum8):
COMFORT = 0x00
COMFORT_MINUS_1 = 0x01
COMFORT_MINUS_2 = 0x02
ECO = 0x03
FROST_PROTECTION = 0x04
OFF = 0x05
class LegrandCableOutletCluster(CustomCluster):
"""Legrand second manufacturer-specific cluster."""
cluster_id = MANUFACTURER_SPECIFIC_CLUSTER_ID_2
name = "CableOutlet"
ep_attribute = "cable_outlet_cluster"
class ServerCommandDefs(BaseCommandDefs):
set_pilot_wire_mode = ZCLCommandDef(
id=0x00,
schema={"mode": PilotWireMode},
direction=Direction.Client_to_Server,
is_manufacturer_specific=True,
)
class Legrand064882CableOutlet(CustomDevice):
signature = {
# <SimpleDescriptor endpoint=1 profile=260 device_type=1
# input_clusters=[0, 3, 4, 6, 5, 64513, 2820, 64576]
# output_clusters=[6, 0, 64513, 5, 25]>
MODELS_INFO: [(f" {LEGRAND}", " Cable outlet")],
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.LEVEL_CONTROL_SWITCH,
INPUT_CLUSTERS: [
Basic.cluster_id,
Identify.cluster_id,
Groups.cluster_id,
OnOff.cluster_id,
Scenes.cluster_id,
MANUFACTURER_SPECIFIC_CLUSTER_ID,
ElectricalMeasurement.cluster_id,
MANUFACTURER_SPECIFIC_CLUSTER_ID_2,
],
OUTPUT_CLUSTERS: [
OnOff.cluster_id,
Basic.cluster_id,
MANUFACTURER_SPECIFIC_CLUSTER_ID,
Scenes.cluster_id,
Ota.cluster_id,
],
},
# <SimpleDescriptor endpoint=242 profile=41440 device_type=102
# input_clusters=[33]
# output_clusters=[33]>
242: {
PROFILE_ID: zgp.PROFILE_ID,
DEVICE_TYPE: zgp.DeviceType.COMBO_BASIC,
INPUT_CLUSTERS: [GreenPowerProxy.cluster_id],
OUTPUT_CLUSTERS: [GreenPowerProxy.cluster_id],
},
},
}
replacement = {
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.LEVEL_CONTROL_SWITCH,
INPUT_CLUSTERS: [
Basic.cluster_id,
Identify.cluster_id,
Groups.cluster_id,
OnOff.cluster_id,
Scenes.cluster_id,
LegrandCluster,
ElectricalMeasurement.cluster_id,
LegrandCableOutletCluster,
],
OUTPUT_CLUSTERS: [
OnOff.cluster_id,
Basic.cluster_id,
LegrandCluster,
Scenes.cluster_id,
Ota.cluster_id,
],
},
242: {
PROFILE_ID: zgp.PROFILE_ID,
DEVICE_TYPE: zgp.DeviceType.COMBO_BASIC,
INPUT_CLUSTERS: [GreenPowerProxy.cluster_id],
OUTPUT_CLUSTERS: [GreenPowerProxy.cluster_id],
},
},
}