diff --git a/IDEAS/Buildings/Components/Window.mo b/IDEAS/Buildings/Components/Window.mo index 6ff9334e5..ae6744b17 100644 --- a/IDEAS/Buildings/Components/Window.mo +++ b/IDEAS/Buildings/Components/Window.mo @@ -453,6 +453,11 @@ can be used to simulate 10 windows by scaling the model of a single window.

The parameter tab Airflow lists optional parameters for adding a self regulating trickle vent.

+

+The RealExpression AExp, which is connected to propsBusInt, outputs the total window area A +instead of only the area of glass A_glass. This partially compensates for the fact that +radiation from/to the frame is not included seperately in the current model implementation. +

Validation

To verify the U-value of your glazing system implementation,