MultiQC doesn't include FastQC reports for trimmed reads #162
Comments
Hi santiagorevale, thanks for testing it. This shouldn't be happening. In fact, the FastP section in MultiQC should display both before-trimming and after-trimming QC data... It worked in older versions of this pipeline properly ... Strange 😅 |
I think the issue is that we are not passing |
Found the issue: when Additionally, it seems that the representation of Fastp merged reads metrics in the MultiQC report is not yet supported. See Multiqc#2826. But we can replace the FastQC (raw) section in the html report by the FastQC (after-trimming) since FastP before tirmming metrics are always present. (just to avoid haivng repeated FastQC sections in the html report) |
Hi Daniel. I think it's better to have both FastQC reports "raw" and "trimmed" in MultiQC. Not only because people is used to them but also because it has some plots that FastP doesn't, like "Adapter Content", which I believe is very important. Regarding the location, I have changed my mind, and I think that it would be best to show them like:
I believe other pipelines include them all as well. |
Solved in #166 |
Description of feature
I believe that having the FastQC reports for the trimmed reads in MultiQC would be a nice useful addition to the report. I would add it after FASP metrics.
The text was updated successfully, but these errors were encountered: