forked from taishin/vendor_mibs
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathHACIP2.mib
701 lines (600 loc) · 19.6 KB
/
HACIP2.mib
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
--------------------------------------------------------------------------------
--
-- System Manager SNMP MIB (HITACHIIPMIP2.MIB)
--
-- All Rights Reserved, Copyright (C) 2008, Hitachi.Ltd.
--
-- Version 04-00-00-00 DATE 2008.04.22
--
--------------------------------------------------------------------------------
SystemManagerHITACHIIPMI-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC-1213;
--------------------------------------------------------------------------------
hitachi OBJECT IDENTIFIER ::= { enterprises 116 }
--------------------------------------------------------------------------------
systemExMib OBJECT IDENTIFIER ::= { hitachi 5 }
systemManagerMibs OBJECT IDENTIFIER ::= { systemExMib 21 }
information OBJECT IDENTIFIER ::= { systemManagerMibs 1 }
--------------------------------------------------------------------------------
-- System Manager
-- information
--------------------------------------------------------------------------------
HitachiHardwareInformations OBJECT IDENTIFIER ::= { information 4 }
--------------------------------------------------------------------------------
temperatureProbeInformation OBJECT IDENTIFIER ::= { HitachiHardwareInformations 2 }
temperatureProbeTable OBJECT-TYPE
SYNTAX SEQUENCE OF TemperatureProbe
ACCESS not-accessible
STATUS mandatory
::= { temperatureProbeInformation 1 }
temperatureProbeEntry OBJECT-TYPE
SYNTAX TemperatureProbe
ACCESS not-accessible
STATUS mandatory
INDEX { index }
::= { temperatureProbeTable 1 }
TemperatureProbe ::= SEQUENCE
{
index INTEGER,
currentReading INTEGER,
status INTEGER,
sensorName DisplayString
}
index OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index into this temperature probe table."
::= { temperatureProbeEntry 1 }
currentReading OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The present temperature reading of this temperature probe in 1/10th
degrees C. 0x8000000 denotes 'unknown'."
::= { temperatureProbeEntry 2 }
status OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the status of the temperature monitored by this temperature
probe.0x00 = Unknown0x01 = OK0x02 = Low(Non-critical)0x03 = High
(Non-critical)0x04 = Low(Critical)0x05 = High(Critical)0x06 = Low
(Non-recoverable)0x07 = High(Non-recoverable)0x08 = Other errors. It is
indicated by a integer value as follows (hexadecimal).
0x00 = Unknown
0x01 = OK
0x02 = Low(Non-critical)
0x03 = High(Non-critical)
0x04 = Low(Critical)
0x05 = High(Critical)
0x06 = Low(Non-recoverable)
0x07 = High(Non-recoverable)
0x08 = Other errors"
::= { temperatureProbeEntry 3 }
sensorName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sensor name. It is expressed in the form of string(ASCII Code)."
::= { temperatureProbeEntry 4 }
--------------------------------------------------------------------------------
fanInformationInformation OBJECT IDENTIFIER ::= { HitachiHardwareInformations 3 }
fanInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF FanInformation
ACCESS not-accessible
STATUS mandatory
::= { fanInformationInformation 1 }
fanInformationEntry OBJECT-TYPE
SYNTAX FanInformation
ACCESS not-accessible
STATUS mandatory
INDEX { index }
::= { fanInformationTable 1 }
FanInformation ::= SEQUENCE
{
index INTEGER,
currentReading INTEGER,
status INTEGER,
sensorName DisplayString
}
index OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index into this FAN information table."
::= { fanInformationEntry 1 }
currentReading OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current number of rotation. 0x80000000 denotes 'unknown'."
::= { fanInformationEntry 2 }
status OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the status of the FAN 0x00 = Unknown0x01 = OK0x02 = Low
(Non-critical)0x03 = High(Non-critical)0x04 = Low(Critical)0x05 = High
(Critical)0x06 = Low(Non-recoverable)0x07 = High(Non-recoverable)0x08 =
Other errors. It is indicated by a integer value as follows
(hexadecimal).
0x00 = Unknown
0x01 = OK
0x02 = Low(Non-critical)
0x03 = High(Non-critical)
0x04 = Low(Critical)
0x05 = High(Critical)
0x06 = Low(Non-recoverable)
0x07 = High(Non-recoverable)
0x08 = Other errors"
::= { fanInformationEntry 3 }
sensorName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sensor name. It is expressed in the form of string(ASCII Code)."
::= { fanInformationEntry 4 }
--------------------------------------------------------------------------------
voltageInformationInformation OBJECT IDENTIFIER ::= { HitachiHardwareInformations 4 }
voltageInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoltageInformation
ACCESS not-accessible
STATUS mandatory
::= { voltageInformationInformation 1 }
voltageInformationEntry OBJECT-TYPE
SYNTAX VoltageInformation
ACCESS not-accessible
STATUS mandatory
INDEX { index }
::= { voltageInformationTable 1 }
VoltageInformation ::= SEQUENCE
{
index INTEGER,
currentReading INTEGER,
status INTEGER,
sensorName DisplayString
}
index OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index into this voltage information table."
::= { voltageInformationEntry 1 }
currentReading OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current voltage. 0x80000000 denotes 'unknown'."
::= { voltageInformationEntry 2 }
status OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the status of the voltage 0x00 = Unknown0x01 = OK0x02 = Low
(Non-critical)0x03 = High(Non-critical)0x04 = Low(Critical)0x05 = High
(Critical)0x06 = Low(Non-recoverable)0x07 = High(Non-recoverable)0x08 =
Other errors. It is indicated by a integer value as follows
(hexadecimal).
0x00 = Unknown
0x01 = OK
0x02 = Low(Non-critical)
0x03 = High(Non-critical)
0x04 = Low(Critical)
0x05 = High(Critical)
0x06 = Low(Non-recoverable)
0x07 = High(Non-recoverable)
0x08 = Other errors"
::= { voltageInformationEntry 3 }
sensorName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sensor name. It is expressed in the form of string(ASCII Code)."
::= { voltageInformationEntry 4 }
--------------------------------------------------------------------------------
powerSupplyUnitInfoInformation OBJECT IDENTIFIER ::= { HitachiHardwareInformations 5 }
powerSupplyUnitInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF PowerSupplyUnitInfo
ACCESS not-accessible
STATUS mandatory
::= { powerSupplyUnitInfoInformation 1 }
powerSupplyUnitInfoEntry OBJECT-TYPE
SYNTAX PowerSupplyUnitInfo
ACCESS not-accessible
STATUS mandatory
INDEX { index }
::= { powerSupplyUnitInfoTable 1 }
PowerSupplyUnitInfo ::= SEQUENCE
{
index INTEGER,
status INTEGER,
sensorName DisplayString
}
index OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index number of the power supply."
::= { powerSupplyUnitInfoEntry 1 }
status OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power supply unit status. It is indicated by a integer value as follows
(hexadecimal).
0x00 = Unknown
0x01 = attached(OK)
0x02 = attached(error)
0x03 = not attached"
::= { powerSupplyUnitInfoEntry 2 }
sensorName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sensor name. It is expressed in the form of string(ASCII Code)."
::= { powerSupplyUnitInfoEntry 3 }
--------------------------------------------------------------------------------
cpuStatusInformation OBJECT IDENTIFIER ::= { HitachiHardwareInformations 6 }
cpuStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpuStatus
ACCESS not-accessible
STATUS mandatory
::= { cpuStatusInformation 1 }
cpuStatusEntry OBJECT-TYPE
SYNTAX CpuStatus
ACCESS not-accessible
STATUS mandatory
INDEX { index }
::= { cpuStatusTable 1 }
CpuStatus ::= SEQUENCE
{
index INTEGER,
status INTEGER,
sensorName DisplayString
}
index OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index number of the CPU."
::= { cpuStatusEntry 1 }
status OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPU status. It is indicated by a integer value as follows (hexadecimal).
0x00 = Unknown
0x01 = attached(OK)
0x02 = attached(error)
0x03 = attached(disabled)
0x04 = not attached"
::= { cpuStatusEntry 2 }
sensorName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sensor name. It is expressed in the form of string(ASCII Code)."
::= { cpuStatusEntry 3 }
--------------------------------------------------------------------------------
maintenanceInformationInformation OBJECT IDENTIFIER ::= { HitachiHardwareInformations 7 }
maintenanceInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF MaintenanceInformation
ACCESS not-accessible
STATUS mandatory
::= { maintenanceInformationInformation 1 }
maintenanceInformationEntry OBJECT-TYPE
SYNTAX MaintenanceInformation
ACCESS not-accessible
STATUS mandatory
INDEX { index }
::= { maintenanceInformationTable 1 }
MaintenanceInformation ::= SEQUENCE
{
index INTEGER,
stand-ByState1 INTEGER,
mainState1 INTEGER,
erasedDate1 DisplayString,
stand-ByState2 INTEGER,
mainState2 INTEGER,
erasedDate2 DisplayString,
stand-ByState3 INTEGER,
mainState3 INTEGER,
erasedDate3 DisplayString,
ponc INTEGER,
poffc INTEGER,
acpic INTEGER,
erasedDate4 DisplayString,
otherData INTEGER
}
index OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index into this maintenance information table."
::= { maintenanceInformationEntry 1 }
stand-ByState1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Manufacturer : Accumulated time(sec.) of Stand-by state."
::= { maintenanceInformationEntry 2 }
mainState1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Manufacturer : Accumulated time(sec.) of Main state."
::= { maintenanceInformationEntry 3 }
erasedDate1 OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Manufacturer : Erased date. It is expressed in the form of string
(ASCII Code)."
::= { maintenanceInformationEntry 4 }
stand-ByState2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maintenance(1) : Accumulated time(sec.) of Stand-by state."
::= { maintenanceInformationEntry 5 }
mainState2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maintenance(1) : Accumulated time(sec.) of Main state."
::= { maintenanceInformationEntry 6 }
erasedDate2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maintenance(1) : Erased date. It is expressed in the form of string
(ASCII Code)."
::= { maintenanceInformationEntry 7 }
stand-ByState3 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maintenance(2) : Accumulated time(sec.) of Stand-by state."
::= { maintenanceInformationEntry 8 }
mainState3 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maintenance(2) : Accumulated time(sec.) of Main state."
::= { maintenanceInformationEntry 9 }
erasedDate3 OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maintenance(2) : Erased date. It is expressed in the form of string
(ASCII Code)."
::= { maintenanceInformationEntry 10 }
ponc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of power on counts."
::= { maintenanceInformationEntry 11 }
poffc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of power off counts."
::= { maintenanceInformationEntry 12 }
acpic OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of AC plug-in counts."
::= { maintenanceInformationEntry 13 }
erasedDate4 OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maintenance Information : Erased date. It is expressed in the form of
string(ASCII Code)."
::= { maintenanceInformationEntry 14 }
otherData OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Reserved data."
::= { maintenanceInformationEntry 15 }
--------------------------------------------------------------------------------
systemBoardInformationInformation OBJECT IDENTIFIER ::= { HitachiHardwareInformations 8 }
systemBoardInformationTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemBoardInformation
ACCESS not-accessible
STATUS mandatory
::= { systemBoardInformationInformation 1 }
systemBoardInformationEntry OBJECT-TYPE
SYNTAX SystemBoardInformation
ACCESS not-accessible
STATUS mandatory
INDEX { index }
::= { systemBoardInformationTable 1 }
SystemBoardInformation ::= SEQUENCE
{
index INTEGER,
cpuName DisplayString
}
index OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index number of the CPU Name."
::= { systemBoardInformationEntry 1 }
cpuName OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPU Name from OEM CPU IDStrings Command. It is expressed in the form of
string(ASCII Code)."
::= { systemBoardInformationEntry 2 }
--------------------------------------------------------------------------------
selInformation OBJECT IDENTIFIER ::= { HitachiHardwareInformations 253 }
selTable OBJECT-TYPE
SYNTAX SEQUENCE OF Sel
ACCESS not-accessible
STATUS mandatory
::= { selInformation 1 }
selEntry OBJECT-TYPE
SYNTAX Sel
ACCESS not-accessible
STATUS mandatory
INDEX { index }
::= { selTable 1 }
Sel ::= SEQUENCE
{
index INTEGER,
triggerSensorNumber INTEGER,
recordType INTEGER,
timestamp DisplayString,
recordData DisplayString,
eventDescription DisplayString
}
index OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index into SEL Table."
::= { selEntry 1 }
triggerSensorNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Sensor Number that triggers this event."
::= { selEntry 2 }
recordType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"02h = system event recordC0h-DFh = OEM timestampedE0h-FFh = OEM
non-timestamped."
::= { selEntry 3 }
timestamp OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time when event was logged. It is expressed in the form of string
(ASCII Code)."
::= { selEntry 4 }
recordData OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Raw data bytes. It is expressed in the form of string(ASCII Code)."
::= { selEntry 5 }
eventDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Description of Event. It is expressed in the form of string
(ASCII Code)."
::= { selEntry 6 }
--------------------------------------------------------------------------------
eventGenerationInformation OBJECT IDENTIFIER ::= { HitachiHardwareInformations 254 }
eventGenerationTable OBJECT-TYPE
SYNTAX SEQUENCE OF EventGeneration
ACCESS not-accessible
STATUS mandatory
::= { eventGenerationInformation 1 }
eventGenerationEntry OBJECT-TYPE
SYNTAX EventGeneration
ACCESS not-accessible
STATUS mandatory
INDEX { eventType }
::= { eventGenerationTable 1 }
EventGeneration ::= SEQUENCE
{
eventType INTEGER,
eventLevel INTEGER,
eventMessage DisplayString,
selRecordData DisplayString
}
eventType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value is the event type."
::= { eventGenerationEntry 1 }
eventLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value is the event level. It is indicated by a integer value as
follows (hexadecimal).
0x01 = Monitor
0x02 = Information
0x04 = OK
0x08 = Non-Critical
0x0A = Critical
0x0C = Non-Recoverable"
::= { eventGenerationEntry 2 }
eventMessage OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Event Message. It is expressed in the form of string(ASCII Code)."
::= { eventGenerationEntry 3 }
selRecordData OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Raw data bytes. It is expressed in the form of string(ASCII Code)."
::= { eventGenerationEntry 4 }
--------------------------------------------------------------------------------
END
--------------------------------------------------------------------------------