mongoimport --uri "mongodb+srv://peterluitjens:n3iBwu5K1k69NXZ@cluster0.mtimiyi.mongodb.net/mcgowan?retryWrites=true&w=majority" --collection pilots --type CSV --drop --file /mcv116.csv
{"_id":{"$oid":"6366de60063d934f1b54fcdd"},"modelNumber":"MCV110A1017","prefix":110,"revisionLetter":"A","connectorNumber":17}
{"_id":{"$oid":"6366e68e063d934f1b54fcde"},"modelNumber":"MCV110A1058","prefix":110,"revisionLetter":"A","connectorNumber":58}
{"_id":{"$oid":"6366e6b8063d934f1b54fce0"},"modelNumber":"MCV110A1014","prefix":"110","revisionLetter":"A","connectorNumber":"14"}
{"_id":{"$oid":"6366e82f063d934f1b54fce1"},"modelNumber":"MCV110A1059","prefix":"110","revisionLetter":"A","connectorNumber":"59"}
{"_id":{"$oid":"6366e84b063d934f1b54fce2"},"modelNumber":"MCV110A1090","prefix":"110","revisionLetter":"A","connectorNumber":"90"}
{"_id":{"$oid":"6366e85a063d934f1b54fce3"},"modelNumber":"MCV110A1000","prefix":"110","revisionLetter":"A","connectorNumber":"00"}
MCV116A1100
MCV116A1101
MCV116A1102
MCV116A1201
MCV116A1203
MCV116A1204
MCV116A1301
MCV116A1302
MCV116A1307
MCV116A1401
MCV116A1402
MCV116A1407
MCV116A1501
MCV116A2100
MCV116A2101
MCV116A2102
MCV116A3101
MCV116A3102
MCV116A3105
MCV116A3201
MCV116A3203
MCV116A3204
MCV116A3206
MCV116A3501
MCV116A3502
MCV116A3602
MCV116A4201
MCV116A4204
MCV116F3112
MCV116F3113
MCV116F4201
MCV116F4204
MCV116F4211
MCV116G4201
MCV116G4204
MCV116G4211
MCV116G4213
MCV116G4214
MCV116C1101
MCV116C1201
MCV116C3101
MCV116C3201
MCV116C1401
Units 5 & 21 are configured with two 2-pin connectors, one for the A/B coil and one for the C/D coil.
Unit 24 is used on all EDCs with a current range of 4-20 mA, with the exception of the Series 42, which has no removable PCP.
Unit 30 has only 2 lead wires terminating into the 4-pin connector
Units 33, 36 & 37 do not have a manual override.
Units 34 - 37 are the result of a product improvement (see PIB 9810 & SB 99001) and should be used with the KVEB style of EDC.
Unit 43 is used on Series 90 EDCs that are Intrinsically Safe with a current range of 4-20 mA.0 to 100
0 to 130
0 to 20
The MCV116 Pressure Control Pilot is specified through a
logical part number as follows: MCV116 X X X XX
DEVICE IDENTITY
CONFIGURATION
A. Standard Control
TYPE (See Table A)
1. Typical use, flow and pressure control
2. Typical use, stand alone
3. Typical use, EDC
COIL TYPE
1. Single coil (23 ohm)
2. Dual coil (15.5, 19 ohm)
3. Single coil (69 ohm)
4. Single coil (106 ohm)
5. Single coil (643 ohm)
CONNECTOR STYLE
00. None (Pigtail)
01. MS
02. Packard 2 pin Weather Pack
03. Packard twin 2 pin Weather Pack
04. Packard 4 pin Weather Pack
05. Packard 2 pin Metri-Pack
06. Packard 4 pin Metri-Pack