You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Polycarbonate, PETG, PET, Acetal, PVC, or Polypropylene
Strap
Polyester, Rubber, Polypropylene, and/or Nylon
Buckle
Plastic
First-aid Measures
Inhalation (breathing)
In case of inhalation of smoke or burnt, consult physician.
Fire-fighting Measures
Flashpoint
N/A
Flammable class
Burnable
Extinguishing media
Class A fire extinguisher
General hazard
Evacuate personal downwind of fire to avoid inhalation of irritation or harmful fumes and smoke.
Hazardous combustion products
Harmful gases
Accidental Release Measures
Collect and treat according to local plastics waste procedures.
Handling and Storage
Handling & Storage
Keep away from flammable substances and ignition sources, and store in cool and dry condition.
Exposure Controls/Personal Protection
Breath protection
Not required
Skin protection
Not required
Ventilation
Not required
Physical and Chemical Properties
Appearance
Colour varies
Stability and Reactivity
Chemical Stability
Stable under normal room conditions of temperature and pressure.
Incompatible products
None
Hazardous decomposition product
N/A
Toxicological Information
Toxicity
The product is non-toxic.
Eye/skin/sensitization effect
This product is not expected to cause significant irritation.
Ecological Information
Not biodegradable.
Disposal Considerations
Treat according to the local plastics waste procedures.
Transport Information
Not regulated or restricted.
Regulatory Information
Minimum Specifications in Urgent Manufacturing Scenarios
Device must provide adequate coverage (CSA Z94.3 Sections 10.2.1/10.2.2/10.3/10.4).
Device should made of optically clear, distortion free, lightweight materials (CSA Standard Z94.3.1-16)
Device should be free of visible defects or flaws that would impede vision (ANSI Z87.1 Section 9.4)
The device should allow adequate space between the wearer’s face and the inner surface of the visor to allow for the use of ancillary equipment (medical/surgical mask, respirator, eyewear, etc.)
Device should fit snugly to afford a good seal to the forehead area and to prevent slippage of the device
Device should withstand impact from sharp or fast projectiles (ANSI Z87.1 Section 9.2 and 9.3, CSA Z94.3 Section 10.1)
If available, device should display anti-fog behavior on inside and outside of shield. (CSA Standard Z94.3.1-16)
User contacting materials should provide adequate material biocompatibility (skin sensitivity and cytotoxic testing) (ISO 10993-5, 10)