Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Expand 100A range to 600A/1000A #6

Open
RafNie opened this issue Oct 8, 2024 · 1 comment
Open

Expand 100A range to 600A/1000A #6

RafNie opened this issue Oct 8, 2024 · 1 comment

Comments

@RafNie
Copy link

RafNie commented Oct 8, 2024

Hi

There is also needed additional change for extending highest range over 100A. Changing of only "Range switch upper/lower limit" is not enough for over 100A measurements.

expand 100A range to 600A
07 = 70 (normally e8)
08 = 17 (normally 03)

expand 100A range to 1000A - only DM1106 chip
07 = 10 (normally e8)
08 = 27 (normally 03)

It seems it is undocumented in application note. I found it on https://www.eevblog.com/forum/testgear/a-look-at-the-uni-t-ut210e/msg1302533/#msg1302533 and I tested and it works well.

@af3556
Copy link
Owner

af3556 commented Oct 30, 2024

Cool; I'll try it out myself and update the doc.