#include "MeComAPI/ComPort/ComPort.h"
#include "MeComAPI/MeCom.h"
#include "temp_moniter.h"
#include "MeComAPI/ComPort/ComPort.h"
#include "MeComAPI/MeCom.h"
#include "configuration.h"
int initMeCom(int MECOM_ADDRESS, int MECOM_INST, int USE_BUILT_IN_PID)
{
MeParLongFields lFields;
/*MeCom port open*/
ComPort_Open(0, 57600);
// if (MeCom_ResetDevice(MECOM_ADDRESS))
// {
// sleep(1);
// fprintf(stderr, "Device Reset OK.\n");
// }
if (MeCom_TEC_Ope_OutputStageInputSelection(MECOM_ADDRESS, MECOM_INST, &lFields, MeGetLimits))
{
if (USE_BUILT_IN_PID)
{
fprintf(stderr, "Using Built-in Temperature Controller\n\n");
lFields.Value = 2; // Temperature Controller
MeCom_TEC_Ope_OutputStageInputSelection(MECOM_ADDRESS, MECOM_INST, &lFields,
MeSet);
}
else
{
fprintf(stderr, "Using Live Current/Voltage\n\n");
lFields.Value = 1; // Live Current/Voltage
MeCom_TEC_Ope_OutputStageInputSelection(MECOM_ADDRESS, MECOM_INST, &lFields,
MeSet);
//setTECVandC(MECOM_ADDRESS, MECOM_INST, 2, 0);
}
return 0;
}
return 1;
}
int setTECVandC(int MECOM_ADDRESS, int MECOM_INST, float Voltage, float Current)
{
MeParFloatFields fFields;
int err;
fFields.Value = Current;
err =
MeCom_TEC_Oth_LiveSetCurrent(MECOM_ADDRESS, MECOM_INST, &fFields, MeSet);
if (err == 0)
{
fprintf(stderr, "LiveSetCurrent failed: Error %d", err);
return err;
}
fFields.Value = Voltage;
err =
MeCom_TEC_Oth_LiveSetVoltage(MECOM_ADDRESS, MECOM_INST, &fFields, MeSet);
if (err == 0)
{
fprintf(stderr, "LiveSetCurrent failed: Error %d", err);
return err;
}
return 0;
}
int getTECVandC(int MECOM_ADDRESS, int MECOM_INST, float *Voltage, float *Current)
{
MeParFloatFields fFields;
int err;
err = MeCom_TEC_Mon_ActualOutputVoltage(MECOM_ADDRESS, MECOM_INST, &fFields,
MeGet);
if (err == 0)
{
fprintf(stderr, "LiveSetCurrent failed: Error %d", err);
return err;
}
*Voltage = fFields.Value;
err = MeCom_TEC_Mon_ActualOutputCurrent(MECOM_ADDRESS, MECOM_INST, &fFields,
MeGet);
if (err == 0)
{
fprintf(stderr, "LiveSetCurrent failed: Error %d", err);
return err;
}
*Current = fFields.Value;
return 0;
}
float getTECTemp(int MECOM_ADDRESS, int MECOM_INST)
{
MeParFloatFields fFields;
MeCom_TEC_Mon_ObjectTemperature(MECOM_ADDRESS, MECOM_INST, &fFields, MeGet);
return fFields.Value;
}