diff --git a/docs/release_notes.rst b/docs/release_notes.rst index a95854db..2214f57c 100644 --- a/docs/release_notes.rst +++ b/docs/release_notes.rst @@ -5,13 +5,19 @@ Release Notes .. Upcoming Release .. ================ +* added water-sourced heat pumps based on upper uncertainty bounds from DEA technology catalogue ("40 Comp. hp, seawater 20 MW") + +* **WARNING**: Costs for central geothermal heating are split into `central geothermal heat source` and `central geothermal-sourced heat pump`. Make sure to use the costs of both for full systems! + +* added geothermal district heating as `central geothermal-sourced heat pump` and `central goethermal heat source` based on DEA technology catalogue ("45.1.a Geothermal DH, 1200m, E") + * added Pyrolysis for biochar * fixed unit formatting in DEA technology data sheets 105 (slow pyrolysis) * fixed DEA technology data sheet name for central water tank storage to point to actual PTES data -* added geothermal district heating as `central geothermal-sourced heat pump` based on DEA technology catalogue ("45.1.a Geothermal DH, 1200m, E") +* Fix minor issues in the code * fix minor issues in the code diff --git a/outputs/costs_2020.csv b/outputs/costs_2020.csv index 49f0405e..0ce70445 100644 --- a/outputs/costs_2020.csv +++ b/outputs/costs_2020.csv @@ -650,6 +650,11 @@ central coal CHP,c_v,0.15,50oC/100oC,"Danish Energy Agency, technology_data_for_ central coal CHP,efficiency,0.485,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","01 Coal CHP: Electricity efficiency, condensation mode, net",2015.0 central coal CHP,investment,2010.6211,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Nominal investment,2015.0 central coal CHP,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Technical lifetime,2015.0 +central excess-heat-sourced heat pump,FOM,0.3003,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Fixed O&M",2015.0 +central excess-heat-sourced heat pump,VOM,1.7884,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Variable O&M",2015.0 +central excess-heat-sourced heat pump,efficiency,5.1,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Total efficiency , net, annual average",2015.0 +central excess-heat-sourced heat pump,investment,704.7435,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Specific investment",2015.0 +central excess-heat-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Technical lifetime",2015.0 central gas CHP,FOM,3.3051,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Fixed O&M",2015.0 central gas CHP,VOM,4.6562,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Variable O&M",2015.0 central gas CHP,c_b,0.96,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Cb coefficient",2015.0 @@ -669,9 +674,13 @@ central gas boiler,VOM,1.164,EUR/MWh_th,"Danish Energy Agency, technology_data_f central gas boiler,efficiency,1.03,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0 central gas boiler,investment,63.4933,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0 central gas boiler,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0 -central geothermal-sourced heat pump,FOM,0.8328,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 +central geothermal heat source,FOM,1.4715,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 +central geothermal heat source,VOM,6.0281,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0 +central geothermal heat source,investment,1625.2908,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 +central geothermal heat source,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0 +central geothermal-sourced heat pump,FOM,3.3935,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 central geothermal-sourced heat pump,VOM,6.0281,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0 -central geothermal-sourced heat pump,investment,2871.7979,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 +central geothermal-sourced heat pump,investment,704.7435,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 central geothermal-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0 central ground-sourced heat pump,FOM,0.3546,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0 central ground-sourced heat pump,VOM,1.0392,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0 @@ -722,6 +731,11 @@ central water pit storage,lifetime,20.0,years,"Danish Energy Agency, technology_ central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0 central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0 central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0 +central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0 +central water-sourced heat pump,VOM,1.8942,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Variable O&M",2015.0 +central water-sourced heat pump,efficiency,3.78,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Total efficiency , net, annual average",2015.0 +central water-sourced heat pump,investment,1058.2216,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Specific investment",2015.0 +central water-sourced heat pump,lifetime,40.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Technical lifetime",2015.0 clean water tank storage,FOM,2.0,%/year,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",, clean water tank storage,investment,69.1286,EUR/m^3-H2O,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,2013.0 clean water tank storage,lifetime,30.0,years,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",, diff --git a/outputs/costs_2025.csv b/outputs/costs_2025.csv index 6f7effbf..810421da 100644 --- a/outputs/costs_2025.csv +++ b/outputs/costs_2025.csv @@ -650,6 +650,11 @@ central coal CHP,c_v,0.15,50oC/100oC,"Danish Energy Agency, technology_data_for_ central coal CHP,efficiency,0.5025,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","01 Coal CHP: Electricity efficiency, condensation mode, net",2015.0 central coal CHP,investment,1989.708,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Nominal investment,2015.0 central coal CHP,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Technical lifetime,2015.0 +central excess-heat-sourced heat pump,FOM,0.3003,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Fixed O&M",2015.0 +central excess-heat-sourced heat pump,VOM,1.7884,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Variable O&M",2015.0 +central excess-heat-sourced heat pump,efficiency,5.2,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Total efficiency , net, annual average",2015.0 +central excess-heat-sourced heat pump,investment,704.7435,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Specific investment",2015.0 +central excess-heat-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Technical lifetime",2015.0 central gas CHP,FOM,3.313,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Fixed O&M",2015.0 central gas CHP,VOM,4.5504,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Variable O&M",2015.0 central gas CHP,c_b,0.98,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Cb coefficient",2015.0 @@ -669,9 +674,13 @@ central gas boiler,VOM,1.1111,EUR/MWh_th,"Danish Energy Agency, technology_data_ central gas boiler,efficiency,1.035,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0 central gas boiler,investment,58.2022,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0 central gas boiler,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0 -central geothermal-sourced heat pump,FOM,0.8253,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 +central geothermal heat source,FOM,1.4691,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 +central geothermal heat source,VOM,6.0453,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0 +central geothermal heat source,investment,1577.4881,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 +central geothermal heat source,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0 +central geothermal-sourced heat pump,FOM,3.2884,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 central geothermal-sourced heat pump,VOM,6.0453,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0 -central geothermal-sourced heat pump,investment,2808.061,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 +central geothermal-sourced heat pump,investment,704.7435,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 central geothermal-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0 central ground-sourced heat pump,FOM,0.3733,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0 central ground-sourced heat pump,VOM,1.183,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0 @@ -722,6 +731,11 @@ central water pit storage,lifetime,22.5,years,"Danish Energy Agency, technology_ central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0 central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0 central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0 +central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0 +central water-sourced heat pump,VOM,1.7884,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Variable O&M",2015.0 +central water-sourced heat pump,efficiency,3.8,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Total efficiency , net, annual average",2015.0 +central water-sourced heat pump,investment,1058.2216,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Specific investment",2015.0 +central water-sourced heat pump,lifetime,40.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Technical lifetime",2015.0 clean water tank storage,FOM,2.0,%/year,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",, clean water tank storage,investment,69.1286,EUR/m^3-H2O,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,2013.0 clean water tank storage,lifetime,30.0,years,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",, diff --git a/outputs/costs_2030.csv b/outputs/costs_2030.csv index 6a549cd5..3d200c7f 100644 --- a/outputs/costs_2030.csv +++ b/outputs/costs_2030.csv @@ -650,6 +650,11 @@ central coal CHP,c_v,0.15,50oC/100oC,"Danish Energy Agency, technology_data_for_ central coal CHP,efficiency,0.52,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","01 Coal CHP: Electricity efficiency, condensation mode, net",2015.0 central coal CHP,investment,1968.7948,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Nominal investment,2015.0 central coal CHP,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Technical lifetime,2015.0 +central excess-heat-sourced heat pump,FOM,0.3504,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Fixed O&M",2015.0 +central excess-heat-sourced heat pump,VOM,2.127,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Variable O&M",2015.0 +central excess-heat-sourced heat pump,efficiency,5.3,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Total efficiency , net, annual average",2015.0 +central excess-heat-sourced heat pump,investment,604.0659,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Specific investment",2015.0 +central excess-heat-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Technical lifetime",2015.0 central gas CHP,FOM,3.3214,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Fixed O&M",2015.0 central gas CHP,VOM,4.4445,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Variable O&M",2015.0 central gas CHP,c_b,1.0,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Cb coefficient",2015.0 @@ -669,9 +674,13 @@ central gas boiler,VOM,1.0582,EUR/MWh_th,"Danish Energy Agency, technology_data_ central gas boiler,efficiency,1.04,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0 central gas boiler,investment,52.9111,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0 central gas boiler,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0 -central geothermal-sourced heat pump,FOM,0.8526,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 +central geothermal heat source,FOM,1.4735,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 +central geothermal heat source,VOM,6.4843,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0 +central geothermal heat source,investment,1529.6854,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 +central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0 +central geothermal-sourced heat pump,FOM,3.7314,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 central geothermal-sourced heat pump,VOM,6.4843,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0 -central geothermal-sourced heat pump,investment,2643.6464,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 +central geothermal-sourced heat pump,investment,604.0659,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 central geothermal-sourced heat pump,lifetime,30.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0 central ground-sourced heat pump,FOM,0.394,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0 central ground-sourced heat pump,VOM,1.3268,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0 @@ -722,6 +731,11 @@ central water pit storage,lifetime,25.0,years,"Danish Energy Agency, technology_ central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0 central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0 central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0 +central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0 +central water-sourced heat pump,VOM,1.6826,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Variable O&M",2015.0 +central water-sourced heat pump,efficiency,3.82,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Total efficiency , net, annual average",2015.0 +central water-sourced heat pump,investment,1058.2216,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Specific investment",2015.0 +central water-sourced heat pump,lifetime,40.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Technical lifetime",2015.0 clean water tank storage,FOM,2.0,%/year,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",, clean water tank storage,investment,69.1286,EUR/m^3-H2O,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,2013.0 clean water tank storage,lifetime,30.0,years,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",, diff --git a/outputs/costs_2035.csv b/outputs/costs_2035.csv index c56ac86c..1c04f1b7 100644 --- a/outputs/costs_2035.csv +++ b/outputs/costs_2035.csv @@ -650,6 +650,11 @@ central coal CHP,c_v,0.15,50oC/100oC,"Danish Energy Agency, technology_data_for_ central coal CHP,efficiency,0.5238,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","01 Coal CHP: Electricity efficiency, condensation mode, net",2015.0 central coal CHP,investment,1948.5297,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Nominal investment,2015.0 central coal CHP,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Technical lifetime,2015.0 +central excess-heat-sourced heat pump,FOM,0.3504,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Fixed O&M",2015.0 +central excess-heat-sourced heat pump,VOM,2.1694,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Variable O&M",2015.0 +central excess-heat-sourced heat pump,efficiency,5.35,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Total efficiency , net, annual average",2015.0 +central excess-heat-sourced heat pump,investment,604.0659,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Specific investment",2015.0 +central excess-heat-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Technical lifetime",2015.0 central gas CHP,FOM,3.3545,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Fixed O&M",2015.0 central gas CHP,VOM,4.3916,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Variable O&M",2015.0 central gas CHP,c_b,1.0,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Cb coefficient",2015.0 @@ -669,9 +674,13 @@ central gas boiler,VOM,1.0582,EUR/MWh_th,"Danish Energy Agency, technology_data_ central gas boiler,efficiency,1.04,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0 central gas boiler,investment,52.9111,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0 central gas boiler,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0 -central geothermal-sourced heat pump,FOM,0.8488,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 +central geothermal heat source,FOM,1.4723,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 +central geothermal heat source,VOM,6.5503,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0 +central geothermal heat source,investment,1505.7841,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 +central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0 +central geothermal-sourced heat pump,FOM,3.6701,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 central geothermal-sourced heat pump,VOM,6.5503,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0 -central geothermal-sourced heat pump,investment,2611.778,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 +central geothermal-sourced heat pump,investment,604.0659,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 central geothermal-sourced heat pump,lifetime,30.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0 central ground-sourced heat pump,FOM,0.4041,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0 central ground-sourced heat pump,VOM,1.373,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0 @@ -722,6 +731,11 @@ central water pit storage,lifetime,25.0,years,"Danish Energy Agency, technology_ central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0 central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0 central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0 +central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0 +central water-sourced heat pump,VOM,1.5768,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Variable O&M",2015.0 +central water-sourced heat pump,efficiency,3.84,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Total efficiency , net, annual average",2015.0 +central water-sourced heat pump,investment,1058.2216,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Specific investment",2015.0 +central water-sourced heat pump,lifetime,40.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Technical lifetime",2015.0 clean water tank storage,FOM,2.0,%/year,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",, clean water tank storage,investment,69.1286,EUR/m^3-H2O,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,2013.0 clean water tank storage,lifetime,30.0,years,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",, diff --git a/outputs/costs_2040.csv b/outputs/costs_2040.csv index 39aaeef8..12bd4c4d 100644 --- a/outputs/costs_2040.csv +++ b/outputs/costs_2040.csv @@ -650,6 +650,11 @@ central coal CHP,c_v,0.15,50oC/100oC,"Danish Energy Agency, technology_data_for_ central coal CHP,efficiency,0.5275,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","01 Coal CHP: Electricity efficiency, condensation mode, net",2015.0 central coal CHP,investment,1928.2647,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Nominal investment,2015.0 central coal CHP,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Technical lifetime,2015.0 +central excess-heat-sourced heat pump,FOM,0.3504,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Fixed O&M",2015.0 +central excess-heat-sourced heat pump,VOM,2.2117,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Variable O&M",2015.0 +central excess-heat-sourced heat pump,efficiency,5.4,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Total efficiency , net, annual average",2015.0 +central excess-heat-sourced heat pump,investment,604.0659,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Specific investment",2015.0 +central excess-heat-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Technical lifetime",2015.0 central gas CHP,FOM,3.3889,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Fixed O&M",2015.0 central gas CHP,VOM,4.3387,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Variable O&M",2015.0 central gas CHP,c_b,1.0,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Cb coefficient",2015.0 @@ -669,9 +674,13 @@ central gas boiler,VOM,1.0582,EUR/MWh_th,"Danish Energy Agency, technology_data_ central gas boiler,efficiency,1.04,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0 central gas boiler,investment,52.9111,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0 central gas boiler,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0 -central geothermal-sourced heat pump,FOM,0.845,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 +central geothermal heat source,FOM,1.4711,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 +central geothermal heat source,VOM,6.6163,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0 +central geothermal heat source,investment,1481.8828,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 +central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0 +central geothermal-sourced heat pump,FOM,3.6088,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 central geothermal-sourced heat pump,VOM,6.6163,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0 -central geothermal-sourced heat pump,investment,2579.9096,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 +central geothermal-sourced heat pump,investment,604.0659,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 central geothermal-sourced heat pump,lifetime,30.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0 central ground-sourced heat pump,FOM,0.4147,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0 central ground-sourced heat pump,VOM,1.4192,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0 @@ -722,6 +731,11 @@ central water pit storage,lifetime,25.0,years,"Danish Energy Agency, technology_ central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0 central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0 central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0 +central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0 +central water-sourced heat pump,VOM,1.4709,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Variable O&M",2015.0 +central water-sourced heat pump,efficiency,3.86,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Total efficiency , net, annual average",2015.0 +central water-sourced heat pump,investment,1058.2216,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Specific investment",2015.0 +central water-sourced heat pump,lifetime,40.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Technical lifetime",2015.0 clean water tank storage,FOM,2.0,%/year,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",, clean water tank storage,investment,69.1286,EUR/m^3-H2O,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,2013.0 clean water tank storage,lifetime,30.0,years,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",, diff --git a/outputs/costs_2045.csv b/outputs/costs_2045.csv index 48fe3680..8060dd8e 100644 --- a/outputs/costs_2045.csv +++ b/outputs/costs_2045.csv @@ -650,6 +650,11 @@ central coal CHP,c_v,0.15,50oC/100oC,"Danish Energy Agency, technology_data_for_ central coal CHP,efficiency,0.5312,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","01 Coal CHP: Electricity efficiency, condensation mode, net",2015.0 central coal CHP,investment,1907.9996,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Nominal investment,2015.0 central coal CHP,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Technical lifetime,2015.0 +central excess-heat-sourced heat pump,FOM,0.3504,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Fixed O&M",2015.0 +central excess-heat-sourced heat pump,VOM,2.0,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Variable O&M",2015.0 +central excess-heat-sourced heat pump,efficiency,5.45,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Total efficiency , net, annual average",2015.0 +central excess-heat-sourced heat pump,investment,604.0659,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Specific investment",2015.0 +central excess-heat-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Technical lifetime",2015.0 central gas CHP,FOM,3.4245,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Fixed O&M",2015.0 central gas CHP,VOM,4.2858,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Variable O&M",2015.0 central gas CHP,c_b,1.0,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Cb coefficient",2015.0 @@ -669,9 +674,13 @@ central gas boiler,VOM,1.0582,EUR/MWh_th,"Danish Energy Agency, technology_data_ central gas boiler,efficiency,1.04,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0 central gas boiler,investment,52.9111,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0 central gas boiler,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0 -central geothermal-sourced heat pump,FOM,0.841,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 +central geothermal heat source,FOM,1.4698,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 +central geothermal heat source,VOM,6.411,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0 +central geothermal heat source,investment,1457.9814,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 +central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0 +central geothermal-sourced heat pump,FOM,3.5475,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 central geothermal-sourced heat pump,VOM,6.411,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0 -central geothermal-sourced heat pump,investment,2548.0411,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 +central geothermal-sourced heat pump,investment,604.0659,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 central geothermal-sourced heat pump,lifetime,30.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0 central ground-sourced heat pump,FOM,0.426,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0 central ground-sourced heat pump,VOM,1.4654,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0 @@ -722,6 +731,11 @@ central water pit storage,lifetime,25.0,years,"Danish Energy Agency, technology_ central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0 central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0 central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0 +central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0 +central water-sourced heat pump,VOM,1.4709,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Variable O&M",2015.0 +central water-sourced heat pump,efficiency,3.86,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Total efficiency , net, annual average",2015.0 +central water-sourced heat pump,investment,1058.2216,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Specific investment",2015.0 +central water-sourced heat pump,lifetime,40.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Technical lifetime",2015.0 clean water tank storage,FOM,2.0,%/year,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",, clean water tank storage,investment,69.1286,EUR/m^3-H2O,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,2013.0 clean water tank storage,lifetime,30.0,years,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",, diff --git a/outputs/costs_2050.csv b/outputs/costs_2050.csv index 7eeae1ab..c8a56517 100644 --- a/outputs/costs_2050.csv +++ b/outputs/costs_2050.csv @@ -650,6 +650,11 @@ central coal CHP,c_v,0.15,50oC/100oC,"Danish Energy Agency, technology_data_for_ central coal CHP,efficiency,0.535,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","01 Coal CHP: Electricity efficiency, condensation mode, net",2015.0 central coal CHP,investment,1887.7345,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Nominal investment,2015.0 central coal CHP,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Technical lifetime,2015.0 +central excess-heat-sourced heat pump,FOM,0.3504,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Fixed O&M",2015.0 +central excess-heat-sourced heat pump,VOM,1.7884,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Variable O&M",2015.0 +central excess-heat-sourced heat pump,efficiency,5.5,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Total efficiency , net, annual average",2015.0 +central excess-heat-sourced heat pump,investment,604.0659,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Specific investment",2015.0 +central excess-heat-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Technical lifetime",2015.0 central gas CHP,FOM,3.4615,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Fixed O&M",2015.0 central gas CHP,VOM,4.2329,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Variable O&M",2015.0 central gas CHP,c_b,1.0,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Cb coefficient",2015.0 @@ -669,9 +674,13 @@ central gas boiler,VOM,1.0582,EUR/MWh_th,"Danish Energy Agency, technology_data_ central gas boiler,efficiency,1.04,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0 central gas boiler,investment,52.9111,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0 central gas boiler,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0 -central geothermal-sourced heat pump,FOM,0.8369,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 +central geothermal heat source,FOM,1.4684,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 +central geothermal heat source,VOM,6.2056,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0 +central geothermal heat source,investment,1434.0801,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 +central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0 +central geothermal-sourced heat pump,FOM,3.4861,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0 central geothermal-sourced heat pump,VOM,6.2056,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0 -central geothermal-sourced heat pump,investment,2516.1727,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 +central geothermal-sourced heat pump,investment,604.0659,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0 central geothermal-sourced heat pump,lifetime,30.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0 central ground-sourced heat pump,FOM,0.4378,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0 central ground-sourced heat pump,VOM,1.5116,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0 @@ -722,6 +731,11 @@ central water pit storage,lifetime,25.0,years,"Danish Energy Agency, technology_ central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0 central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0 central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0 +central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0 +central water-sourced heat pump,VOM,1.4709,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Variable O&M",2015.0 +central water-sourced heat pump,efficiency,3.86,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Total efficiency , net, annual average",2015.0 +central water-sourced heat pump,investment,1058.2216,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Specific investment",2015.0 +central water-sourced heat pump,lifetime,40.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Technical lifetime",2015.0 clean water tank storage,FOM,2.0,%/year,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",, clean water tank storage,investment,69.1286,EUR/m^3-H2O,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,2013.0 clean water tank storage,lifetime,30.0,years,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",, diff --git a/scripts/compile_cost_assumptions.py b/scripts/compile_cost_assumptions.py index 0d9da36f..d5dca78c 100644 --- a/scripts/compile_cost_assumptions.py +++ b/scripts/compile_cost_assumptions.py @@ -87,6 +87,9 @@ # 'solid biomass power CC': '09a Wood Chips extract. plant', 'central air-sourced heat pump': '40 Comp. hp, airsource 3 MW', 'central geothermal-sourced heat pump': '45.1.a Geothermal DH, 1200m, E', + 'central geothermal heat source': '45.1.a Geothermal DH, 1200m, E', + 'central excess-heat-sourced heat pump': '40 Comp. hp, excess heat 10 MW', + 'central water-sourced heat pump': '40 Comp. hp, seawater 20 MW', 'central ground-sourced heat pump': '40 Absorption heat pump, DH', 'central resistive heater': '41 Electric Boilers', 'central gas boiler': '44 Natural Gas DH Only', @@ -170,6 +173,9 @@ 'solar': '', 'central air-sourced heat pump': 'J:K', 'central geothermal-sourced heat pump': 'H:K', + 'central geothermal heat source': 'H:K', + 'central excess-heat-sourced heat pump': 'H:K', + 'central water-sourced heat pump': 'H:K', 'central ground-sourced heat pump': 'I:J', 'central resistive heater': 'I:J', 'central gas boiler': 'I:J', @@ -497,6 +503,8 @@ def get_data_DEA(tech, data_in, expectation=None): usecols = "A:E" elif tech in ['Fischer-Tropsch', 'Haber-Bosch', 'air separation unit']: usecols = "B:F" + elif tech in ["central water-sourced heat pump"]: + usecols = "B,I,K" else: usecols = "B:G" @@ -524,6 +532,33 @@ def get_data_DEA(tech, data_in, expectation=None): excel.dropna(axis=0, how="all", inplace=True) # print(excel) + if tech in ["central water-sourced heat pump"]: + # use only upper uncertainty range for systems without existing water intake + # convert "Uncertainty (2025)"" to "2025", "Uncertainty (2050)"" to "2050" (and so on if more years are added) + this_years = excel.loc[:,excel.iloc[1,:]=="Lower"].iloc[0,:].str.slice(-5,-1).astype(int) + # get values in upper uncertainty range + excel = excel.loc[:,excel.iloc[1,:]=="Upper"] + # rename columns to years constructed above + excel.columns = this_years + # add missing years + for y in years: + if y not in excel.columns: + excel[y] = np.nan + + # Sort columns by year + excel = excel.reindex(sorted(excel.columns), axis=1) + + # drop row Energy/technical data (not needed, contains strings which break interpolation) + excel = excel[~excel.index.str.contains("Energy/technical data")] + + # Interpolate to fill in NaN values + excel = excel.astype(float).interpolate(axis=1, method="linear") + # Extrapolation for missing values (not native in pandas) + # Currently, this is only first column (2020), since DEA data is available for 2025 and 2050 + if excel.iloc[:, 0].isnull().all(): + excel.iloc[:, 0] = excel.iloc[:, 1] + (excel.iloc[:, 1] - excel.iloc[:, 2]) / (excel.columns[2] - excel.columns[1]) * (excel.columns[1] - excel.columns[0]) + + if 2020 not in excel.columns: selection = excel[excel.isin([2020])].dropna(how="all").index excel.columns = excel.loc[selection].iloc[0, :].fillna("Technology", limit=1) @@ -591,7 +626,10 @@ def get_data_DEA(tech, data_in, expectation=None): 'Feedstock Consumption', # biochar pyrolysis 'Methane Output', 'CO2 Consumption', - 'Hydrogen Consumption'] + 'Hydrogen Consumption', + ' - of which is equipment excluding heat pump', + ' - of which is heat pump including its installation', + ] df = pd.DataFrame() for para in parameters: @@ -686,6 +724,12 @@ def get_data_DEA(tech, data_in, expectation=None): if "biochar pyrolysis" in tech: df = biochar_pyrolysis_harmonise_dea(df) + + elif tech == "central geothermal-sourced heat pump": + df.loc["Nominal investment (MEUR per MW)"] = df.loc[" - of which is heat pump including its installation"] + + elif tech == "central geothermal heat source": + df.loc["Nominal investment (MEUR per MW)"] = df.loc[" - of which is equipment excluding heat pump"] df_final = pd.DataFrame(index=df.index, columns=years)