Notifications
You must be signed in to change notification settings - Fork 1.7k
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
MOES/Tuya TS0601_dimmer 1 Gang no brightness control #13174
Comments
I have updated the log data to the correct info. It seems to me this switch has non-standard, or just differently implemented clusters than other similar dimmers. I did make the following discovery. I am able to get control over brightness by using the 'exposes' page and sliding both the In my testing, the dimmer always seems to respond with the last value you intended to set, but the dimmer does NOT ever ACTUALLY go to the set point until you move both sliders, and fiddle with it. I am still trying to define the consistent behavior to make the actual change in brightness invoke. I used MQTT-X and tried manually publishing the brightness and max_brightness, and while the switch accepts and reports the set point, it does not actually go to it, no matter how much i fiddle with commands from MQTT-X. I can however set the state, on or off, manually and the switch does respond to that. I think my next step is to see what exactly is being sent and received to and from the switch by the zigbee-heardsman system. I believe we are only a few adjustments away from having this working for this particular dimmer. |
This issue is stale because it has been open 30 days with no activity. Remove stale label or comment or this will be closed in 7 days |
This is still an issue with the latest edge as of 8/22/2022. Commenting to keep issue open. |
This sounds like the problem I'm having, but using ZHA: zigpy/zha-device-handlers#1750 Happy to help with extra logs and data. |
@bort900 can you provide the data/database.db entry of this device? |
Thank you kindly. please see below.
|
Could you check if the issue is fixed with the following external converter: const fz = require('zigbee-herdsman-converters/converters/fromZigbee');
const tz = require('zigbee-herdsman-converters/converters/toZigbee');
const exposes = require('zigbee-herdsman-converters/lib/exposes');
const reporting = require('zigbee-herdsman-converters/lib/reporting');
const extend = require('zigbee-herdsman-converters/lib/extend');
const utils = require('zigbee-herdsman-converters/lib/utils');
const ota = require('zigbee-herdsman-converters/lib/ota');
const tuya = require('zigbee-herdsman-converters/lib/tuya');
const e = exposes.presets;
const ea = exposes.access;
const tzLocal = {
tuya_dimmer_level: {
key: ['brightness_min', 'min_brightness', 'max_brightness', 'brightness', 'brightness_percent', 'level'],
convertSet: async (entity, key, value, meta) => {
// upscale to 1000
let newValue;
let dp = tuya.dataPoints.dimmerLevel;
if (['_TZE200_3p5ydos3', '_TZE200_9i9dt8is', '_TZE200_dfxkcots', '_TZE200_w4cryh2i', '_TZE200_ip2akl4w'].includes(meta.device.manufacturerName)) {
dp = tuya.dataPoints.eardaDimmerLevel;
}
if (key === 'brightness_min') {
if (value >= 0 && value <= 100) {
newValue = utils.mapNumberRange(value, 0, 100, 0, 1000);
dp = tuya.dataPoints.dimmerLevel;
} else {
throw new Error('Dimmer brightness_min is out of range 0..100');
}
} else if (key === 'min_brightness') {
if (value >= 1 && value <= 255) {
newValue = utils.mapNumberRange(value, 1, 255, 0, 1000);
dp = tuya.dataPoints.dimmerMinLevel;
} else {
throw new Error('Dimmer min_brightness is out of range 1..255');
}
} else if (key === 'max_brightness') {
if (value >= 1 && value <= 255) {
newValue = utils.mapNumberRange(value, 1, 255, 0, 1000);
dp = tuya.dataPoints.dimmerMaxLevel;
} else {
throw new Error('Dimmer min_brightness is out of range 1..255');
}
} else if (key === 'level') {
if (value >= 0 && value <= 1000) {
newValue = Math.round(Number(value));
} else {
throw new Error('Dimmer level is out of range 0..1000');
}
} else if (key === 'brightness_percent') {
if (value >= 0 && value <= 100) {
newValue = utils.mapNumberRange(value, 0, 100, 0, 1000);
} else {
throw new Error('Dimmer brightness_percent is out of range 0..100');
}
} else { // brightness
if (value >= 0 && value <= 254) {
newValue = utils.mapNumberRange(value, 0, 254, 0, 1000);
} else {
throw new Error('Dimmer brightness is out of range 0..254');
}
}
// Always use same transid as tuya_dimmer_state (https://github.com/Koenkk/zigbee2mqtt/issues/6366)
await tuya.sendDataPointValue(entity, dp, newValue, 'dataRequest', 1);
},
}
}
const fzLocal = {
tuya_dimmer: {
cluster: 'manuSpecificTuya',
type: ['commandDataResponse', 'commandDataReport'],
convert: (model, msg, publish, options, meta) => {
const dpValue = tuya.firstDpValue(msg, meta, 'tuya_dimmer');
const value = tuya.getDataValue(dpValue);
if (dpValue.dp === tuya.dataPoints.state) {
return {state: value ? 'ON': 'OFF'};
} else if (meta.device.manufacturerName === '_TZE200_swaamsoy') {
// https://github.com/Koenkk/zigbee-herdsman-converters/pull/3004
if (dpValue.dp === 2) {
if (value < 10) {
tuya.logUnexpectedDataValue('tuya_dimmer', msg, dpValue, meta, 'brightness', 10, 1000);
}
return {brightness: utils.mapNumberRange(value, 10, 1000, 0, 254)};
}
} else if (['_TZE200_3p5ydos3', '_TZE200_9i9dt8is', '_TZE200_dfxkcots', '_TZE200_w4cryh2i', '_TZE200_ip2akl4w']
.includes(meta.device.manufacturerName)) {
if (dpValue.dp === tuya.dataPoints.eardaDimmerLevel) {
return {brightness: utils.mapNumberRange(value, 0, 1000, 0, 254)};
} else if (dpValue.dp === tuya.dataPoints.dimmerMinLevel) {
return {min_brightness: utils.mapNumberRange(value, 0, 1000, 1, 255)};
} else if (dpValue.dp === tuya.dataPoints.dimmerMaxLevel) {
return {max_brightness: utils.mapNumberRange(value, 0, 1000, 1, 255)};
} else {
tuya.logUnexpectedDataPoint('tuya_dimmer', msg, dpValue, meta);
}
} else {
if (dpValue.dp !== tuya.dataPoints.dimmerLevel) {
tuya.logUnexpectedDataPoint('tuya_dimmer', msg, dpValue, meta);
}
if (dpValue.datatype !== tuya.dataTypes.value) {
tuya.logUnexpectedDataType('tuya_dimmer', msg, dpValue, meta);
} else {
if (value < 10) {
tuya.logUnexpectedDataValue('tuya_dimmer', msg, dpValue, meta, 'brightness', 10, 1000);
}
return {brightness: utils.mapNumberRange(value, 10, 1000, 0, 254), level: value};
}
}
},
}
}
const definition = {
fingerprint: [
{modelID: 'TS0601', manufacturerName: '_TZE200_ip2akl4w'},
],
model: 'TS0601_dimmer',
vendor: 'TuYa',
description: 'Zigbee smart dimmer',
fromZigbee: [fzLocal.tuya_dimmer, fz.ignore_basic_report],
toZigbee: [tz.tuya_dimmer_state, tzLocal.tuya_dimmer_level],
configure: async (device, coordinatorEndpoint, logger) => {
const endpoint = device.getEndpoint(1);
await reporting.bind(endpoint, coordinatorEndpoint, ['genOnOff', 'genLevelCtrl']);
},
exposes: [e.light_brightness().withMinBrightness().withMaxBrightness().setAccess(
'state', ea.STATE_SET).setAccess('brightness', ea.STATE_SET).setAccess(
'min_brightness', ea.STATE_SET).setAccess('max_brightness', ea.STATE_SET)],
whiteLabel: [
{vendor: 'Larkkey', model: 'ZSTY-SM-1DMZG-EU'},
{vendor: 'Earda', model: 'EDM-1ZAA-EU'},
{vendor: 'Earda', model: 'EDM-1ZAB-EU'},
{vendor: 'Earda', model: 'EDM-1ZBA-EU'},
{vendor: 'Mercator Ikuü', model: 'SSWD01'},
{vendor: 'Moes', model: 'ZS-USD'},
],
};
module.exports = definition;
external_converters:
- ext_converter.js
|
@Koenkk I am confirming this external converter did fix the issue. Lights turn on and off and go to the set dimming level each time. Thank you so much for your time on this! |
@bort900 great, can you also check with this converter? https://gist.github.com/Koenkk/9c36da807c3768a85aaed9a352c74e96 |
@Koenkk Yes, that converter appears to work as well. Big thank you again! Happy to test more. And in fact, i have 2, 3, and 4 gang versions of this dimmer i never setup because the 1 gang was not working. I am happy to test and report on those as well. |
@bort900 please test, then we can immediately fix those. I'm interested in how z2m recognizes them. |
Will do! I will get them labbed up this weekend. |
This issue is stale because it has been open 30 days with no activity. Remove stale label or comment or this will be closed in 7 days |
What happened?
Product Link: 1 Gang US White: https://www.aliexpress.com/item/3256803386112753.html
I have a MOES branded Tuya TS0601_dimmer wall dimmer and it will respond to on/off commands but not brightness commands. The min and max do not seem responsive either. You can manually adjust the dimmer at the switch the brightness and state are reflected properly, but you cant set brightness from Zigbee2MQTT or homeassistant.
This issue sounds similar to this one here, but could be unrelated.
You'll see in the log there is lots of extra garbage this unit seems to report that has nothing to do with dimming. Perhaps the zigbee-heardsman system is getting tripped up the extra values or this manufacturer changed their protocol slightly?
The same behavior is observed with 1.26.0-dev commit: [6377746]
What did you expect to happen?
When adjusting the brightness i expect the dimmer switch to respond according to the new value set by adjusting the brightness value from Zigbee2MQTT
How to reproduce it (minimal and precise)
Attempt to set the brightness via the 'Exposes' interface to any arbitrary value and then move it again. It will be unresponsive.
Zigbee2MQTT version
1.26.0
Adapter firmware version
2022021
Adapter
SONOFF Zigbee 3.0 USB adapter
Debug log
The text was updated successfully, but these errors were encountered: