From 2cf7702d65cce20dd8c1949848b5a86111096483 Mon Sep 17 00:00:00 2001 From: Koen Kanters Date: Sat, 25 Jan 2020 17:44:09 +0100 Subject: [PATCH] DJT11LM strength docs. https://github.com/Koenkk/zigbee2mqtt/issues/2258 --- docs/devices/DJT11LM.md | 2 ++ 1 file changed, 2 insertions(+) diff --git a/docs/devices/DJT11LM.md b/docs/devices/DJT11LM.md index e1105ce2bb914..29639d120cc4d 100644 --- a/docs/devices/DJT11LM.md +++ b/docs/devices/DJT11LM.md @@ -24,6 +24,8 @@ Then press the button again every 2 seconds (maximum 20 times). *NOTE: When you fail to pair a device, try replacing the battery, this could solve the problem.* +### Meaning of `strength` value +The `strength` value, which is reported every 300 seconds after vibration is detected, is the max strength measured during a period of 300 second. ### Sensitivity The sensitivity can be changed by publishing to `zigbee2mqtt/[FRIENDLY_NAME]/set`