Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathICD.adb
271 lines (235 loc) · 8.12 KB
/
ICD.adb
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
with Ada.Text_IO; use Ada.Text_IO;
with Ada.Integer_Text_IO; use Ada.Integer_Text_IO;
with Measures;
with Heart;
with HRM;
package body ICD is
time : constant Integer := 5;
procedure Init(Icd :out ICDType) is
begin
Icd.Rate := Measures.BPM'First;
Icd.Last6Rate := (0,0,0,0,0,0);
Icd.IsOn := False;
--Tachycardia realated variables
Icd.TachycardiaBound := Measures.TUB'First;
Icd.isTachycardia := False;
Icd.isInImpulseProcess := False;
Icd.Impulse := 0;
Icd.ImpulseRate := 0;
Icd.Offset := 0;
Icd.TickToNextImpulse := 0;
Icd.Signal := 10;
--Fibrillation realated variables
Icd.FibrillationBound := Measures.FUB'First;
Icd.isFibrillation := False;
Icd.isWait := False;
Icd.waitAfterShock := 10;
Icd.AbnormalNum := 0;
end Init;
procedure On(Icd: out ICDType ; Hm : in out HRM.HRMType; Gen : out ImpulseGenerator.GeneratorType; Hrt: in out Heart.HeartType) is
begin
-- re-set the Icd, which setting all variable to default value, excepting TachycardiaBound
-- and FibrillationBound, because they might be changed in off mode
Icd.Rate := Measures.BPM'First;
Icd.Last6Rate := (0,0,0,0,0,0);
Icd.IsOn := True;
--Tachycardia realated variables
Icd.isTachycardia := False;
Icd.isInImpulseProcess := False;
Icd.Impulse := 0;
Icd.ImpulseRate := 0;
Icd.Offset := 0;
Icd.TickToNextImpulse := 0;
Icd.Signal := 10;
--Fibrillation realated variables
Icd.isFibrillation := False;
Icd.isWait := False;
Icd.waitAfterShock := 10;
Icd.AbnormalNum := 0;
-- turn on Hrm and Gen
HRM.On(Hm, Hrt);
ImpulseGenerator.On(Gen);
-- re-init Heart
Heart.Init(Hrt);
-- Get an initial reading for the heart
HRM.GetRate(Hm, Icd.Rate);
end On;
procedure Off(Icd: out ICDType ; Hm : in out HRM.HRMType; Gen : out ImpulseGenerator.GeneratorType) is
begin
-- Since ICD is the controller, it should never be turned down, only turn down Hrm and Gen
Icd.IsOn := False;
HRM.Off(Hm);
ImpulseGenerator.Off(Gen);
end Off;
function IsOn(Icd : in ICDType) return Boolean is
begin
return Icd.IsOn;
end IsOn;
procedure GetRate (Icd : in ICDType ; Rate : out Measures.BPM) is
begin
if Icd.IsOn then
Rate := Icd.Rate;
else
Rate := Measures.BPM'First;
end if;
end GetRate;
procedure isTachycardia(Icd : in out ICDType) is
begin
-- check wheter the heart rate is higher than the upper bound
if Icd.Rate >= Icd.TachycardiaBound then
Icd.isTachycardia := True;
else
Icd.isTachycardia := False;
end if;
end isTachycardia;
procedure isFibrillation(Icd : in out ICDType) is
begin
-- if there are 3 abnormal rate in 5 ticks then it is considered as a Fibrillation
GetAbnormalNum(Icd);
if Icd.AbnormalNum > 3 then
Icd.isFibrillation := true;
-- when a Fibrillation is detected Tachycardia detection should be turn off, since Fibrillationis more serious than Tachycardia
Icd.isTachycardia := False;
else
Icd.isFibrillation := False;
end if;
end isFibrillation;
procedure GetAbnormalNum (Icd : in out ICDType) is
begin
Icd.AbnormalNum := 0;
for I in Integer range 0..4 loop
if abs(Icd.Last6Rate(I) - Icd.Last6Rate(I + 1)) >= Icd.FibrillationBound then
Icd.AbnormalNum := Icd.AbnormalNum + 1;
end if;
end loop;
end GetAbnormalNum;
-- indicates that the icd should wait 1s after a 30 j shock was given
procedure isWait(Icd : in out ICDType) is
begin
if Icd.isWait then
Icd.waitAfterShock := Icd.waitAfterShock -1 ;
if Icd.waitAfterShock = 0 then
Icd.waitAfterShock := 10;
Icd.isWait := False;
end if;
end if;
end isWait;
procedure CalculateImpluse(Icd : out ICDType) is
begin
-- reset impulse to 0 before each caculation
Icd.Impulse := 0;
--check whether there is 1s after giving a shock
if not Icd.isWait then
-- Check whether there is a Fibrillation
if Icd.isFibrillation then
Put_Line("May DAy May Day, Fibrillation is detected!");
-- since Fibrillation is heavier than Tachycardia then if a Fibrillation is detected, set impulse to 30, and terminate all in process impulse
Icd.Impulse := 30;
Icd.isInImpulseProcess := False;
Icd.isWait := True;
-- reset tick and sinal to it's defualt value
Icd.TickToNextImpulse := 0;
Icd.Signal := 10;
end if;
if Icd.isTachycardia and not Icd.isInImpulseProcess then
Put_Line("A ventricular tachycardia was detected ");
end if;
-- check whether there is a Tachycardia detected or a impulse treatment in process
if (Icd.isTachycardia or Icd.isInImpulseProcess) then
-- set the isInImpulseProcess to true indicatong that there is a treatment in process it will be changed to false when a process is finised (signal == 0)
Icd.isInImpulseProcess := True;
--caculate the bpm, which equals Upper Bound + 15
Icd.ImpulseRate := Icd.TachycardiaBound + 15;
--caculate the offset between inpulse
Icd.offset := 600 / Icd.ImpulseRate;
if Icd.TickToNextImpulse = 0 then
-- if yes print "--Already in impulse procedure"
Put("-- in impulse treatment procedure, there is");
Put(Item => Icd.Signal);
Put(" more singal to go");
New_Line;
-- set Impluse value to 2 j;
Icd.Impulse := 2;
-- update how many signal remains need to send
Icd.Signal := Icd.Signal - 1;
-- set next impulse time to offset once it is 0
Icd.TickToNextImpulse := Icd.offset -1 ;
else
Icd.Impulse := 0;
Icd.TickToNextImpulse := Icd.TickToNextImpulse - 1;
end if;
-- if singal equals to 0 means the treatment is fninished then set the isTachycardia to False set TickToNextImpulse to default 0 reset singal to 10
if Icd.Signal = 0 then
Icd.TickToNextImpulse := 0;
Icd.Signal := 10;
Icd.isInImpulseProcess := False;
end if;
end if;
end if;
end CalculateImpluse;
procedure setFibrillationBound (Icd : in out ICDType; ub : in Integer) is
begin
if not Icd.IsOn then
-- make sure the Ub is in the range
Icd.FibrillationBound := Measures.LimitFUB(ub);
Put("-- The Fibrillation Bound has been changed to");
Put(Item => Icd.FibrillationBound, width => 0);
New_Line;
else
Put_Line("-- The Fibrillation Bound can only be changed in Off mode");
Put_Line("-- Please use Switch to change the mode");
Put("-- The Fibrillation Upper Bound is still ");
Put(Item => Icd.FibrillationBound, width => 0);
New_Line;
end if;
end setFibrillationBound;
procedure setTachycardiaBound (Icd : in out ICDType; ub : in Integer) is
begin
if not Icd.IsOn then
-- make sure the Ub is in the range
Icd.TachycardiaBound := Measures.LimitTUB(ub);
Put("-- The Tachycardia Upper Bound has been changed to");
Put(Item => Icd.TachycardiaBound, width => 0);
New_Line;
else
Put_Line("-- The Tachycardia UpperBound can only be changed in Off mode");
Put_Line("-- Please use Switch to change the mode");
Put("-- The Tachycardia Upper Bound is still ");
Put(Item => Icd.TachycardiaBound, width => 0);
New_Line;
end if;
end setTachycardiaBound;
procedure BPMArrayUpdate (Icd : in out ICDType) is
begin
for I in Integer range 0..4 loop
Icd.Last6Rate(4 - I + 1) := Icd.Last6Rate(4 -I);
end loop;
end BPMArrayUpdate;
procedure Tick(Icd : in out ICDType; Hm : in HRM.HRMType; Gen : in out ImpulseGenerator.GeneratorType) is
begin
-- read the heart rate from hrm
HRM.GetRate(Hm, Icd.Rate);
BPMArrayUpdate(icd);
Icd.Last6Rate(0) := Icd.Rate;
-- Put(" This last 6 Rate ");
-- Put(Item => Icd.Last6Rate(0));
-- Put(Item => Icd.Last6Rate(1));
-- Put(Item => Icd.Last6Rate(2));
-- Put(Item => Icd.Last6Rate(3));
-- Put(Item => Icd.Last6Rate(4));
-- Put(Item => Icd.Last6Rate(5));
New_Line;
--check whether there is 1s after giving a shock
isWait(icd);
--check whether there is a Tachycardia
isTachycardia(Icd);
--check whether there is a Fibrillation
isFibrillation(Icd);
CalculateImpluse(Icd);
-- calculate and set the impluse
ImpulseGenerator.SetImpulse(Gen, Icd.Impulse);
Put("Heart rate = ");
Put(Item => Icd.Rate);
New_Line;
end Tick;
end ICD;