Documentation of the Daikin binding bundle.
This binding allows you to monitor and control a Daikin air conditioner/heat pump via openHAB. In order for this to work a KKRP01A Online Controller must be installed in your Daikin unit and connected to your LAN.
There is a list of units that are compatible with the KKRP01A here and instructions on how to install and configure the controller here.
The KKRP01A has a built in web server which allows you to poll the devices status (via GET requests) as well as send commands (via POST requests) to turn the unit on/off, change its mode, etc.
You need to let openHAB know where to find the KKRP01A web server and set how often you would like the binding to refresh any status items (send a GET request).
The binding supports more than one KKRP01A if required.
############################# Daikin Binding #############################
# the refresh interval (in ms)
daikin:refresh=60000
# where <name> is used in your item bindings
# where WIRELESS or WIRED is the type of your Daikin Remote Control Device (BRP069A42 is a WIRELESS Device)
daikin:<name>.host=<WIRELESS|WIRED>@<ipaddress|host>
#daikin:<name>.username=<not used>
#daikin:<name>.password=<not used>
The binding supports both inbound and outbound bindings.
// the temperature/humidity at the indoor unit
Number DaikinTempIn "Temp Inside [%.1f °C]" { daikin="<name>:tempin" }
Number DaikinHumidityIn "Humidity Inside [%.1f %%]" { daikin="<name>:humidityin" }
// the temperature at the outdoor unit
Number DaikinTempOut "Temp Outside [%.1f °C]" { daikin="<name>:tempout" }
// power
Switch DaikinPower "Power" { daikin="<name>:power" }
// mode of operation - one of Auto/Dry/Cool/Heat/Fan/Night
Number DaikinMode "Mode [%.0f]" { daikin="<name>:mode" }
// temperature set point
Number DaikinTemp "Temp [%.0f °C]" { daikin="<name>:temp" }
// fan mode - one of Auto/F1/F2/F3/F4/F5
Number DaikinFan "Fan [%.0f]" { daikin="<name>:fan" }
// swing mode - one of Off/UpDown
Number DaikinSwing "Swing [%.0f]" { daikin="<name>:swing" }
// timer mode - one of Off-Off/Off-On/On-Off/On-On (start/end timers)
Number DaikinTimer "Timer [%.0f]" { daikin="<name>:timer" }
Text item=DaikinTempOut
Switch item=DaikinPower
Text item=DaikinTemp
Text item=DaikinHumidityIn
Switch item=DaikinMode mappings=[0="Auto", 2="Dry", 3="Cool", 4="Heat", 6="Fan"]
Setpoint item=DaikinTemp minValue="16" maxValue="30" step="1"
Switch item=DaikinFan mappings=[0="Auto", 1="F1", 2="F2", 3="F3", 4="F4", 5="F5"]
Switch item=DaikinSwing mappings=[0="Off", 1="Vertical", 2="Horizontal", 3="Hor/Vert"]
The KKRP01A supports user authentication however this is not currently supported by the binding.