import digitalio
import board
import busio
from atm90e32 import ATM90e32
from adafruit_bus_device.spi_device import SPIDevice
# ***** CALIBRATION SETTINGS *****/
lineFreq = 4485 # 4485 for 60 Hz (North America)
# 389 for 50 hz (rest of the world)
PGAGain = 21 # 21 for 100A (2x), 42 for >100A (4x)
VoltageGain = 42080 # 42080 - 9v AC transformer.
# 32428 - 12v AC Transformer
CurrentGainCT1 = 25498 # 38695 - SCT-016 120A/40mA
CurrentGainCT2 = 25498 # 25498 - SCT-013-000 100A/50mA
# 46539 - Magnalab 100A w/ built in burden resistor
spi_bus = busio.SPI(board.SCK, MISO=board.MISO, MOSI=board.MOSI)
cs = digitalio.DigitalInOut(board.D10)
energy_sensor = ATM90e32(spi_bus, cs, lineFreq, PGAGain,
VoltageGain, CurrentGainCT1, 0, CurrentGainCT2)
sys0 = energy_sensor.sys_status0
print('Sys status: S0:{:#04x} S1:{:#04x}'.format(sys0, energy_sensor.sys_status1)
)
print('meter status E0: {:#04x} S1:{:#04x}'.format(
energy_sensor.meter_status0, energy_sensor.meter_status1))
print('Last SPI read: {:#04x}'.format(energy_sensor.lastSpiData))
if (sys0 == 0xFFFF or sys0 == 0):
print('ERROR: not receiving data from the energy meter')
exit(0)
voltageA = energy_sensor.line_voltageA
voltageC = energy_sensor.line_voltageC
if (lineFreq == 4485): # split single phase
totalVoltage = voltageA + voltageC
else:
totalVoltage = voltageA # 220-240v
print('Voltage 1: {}V'.format(voltageA))
print('Voltage 2: {}V'.format(voltageC))
print('Current 1: {}A'.format(energy_sensor.line_currentA))
print('Current 2: {}A'.format(energy_sensor.line_currentC))
print('Frequency: {}Hz'.format(energy_sensor.frequency))
print('Active Power: {}W'.format(energy_sensor.active_power))