Data Plane Warning
Data Plane OpenAPI specs
Schema with type: {{type}} has unrecognized format: {{format}}
Every schema should specify a well-defined combination of type
and format
.
format
is required for type integer and number, optional for type string,
and not allowed for any other types.
The well-defined type/format combinations are:
type: integer
format | description | comments |
---|---|---|
int32 | signed 32 bits | from oas2 |
int64 | signed 64 bits | from oas2 |
unixtime | Unix time stamp | from AutoRest |
type: number
format | description | comments |
---|---|---|
float | 32 bit floating point | from oas2 |
int64 | 64 bit floating point | from oas2 |
decimal | 128 bit floating point | from AutoRest |
type: string
format | description | comments |
---|---|---|
byte | base64 encoded characters | from oas2 |
binary | any sequence of octets | from oas2 |
date | RFC3339 full-date | from oas2 |
date-time | RFC3339 date-time | from oas2 |
password | sensitive value | from oas2 |
char | from AutoRest | |
time | from AutoRest | |
date-time-rfc1123 | from AutoRest | |
date-time-rfc7231 | from AutoRest | |
duration | from AutoRest | |
uuid | from AutoRest | |
base64url | from AutoRest | |
url | from AutoRest | |
uri | from AutoRest | |
odata-query | from AutoRest | |
certificate | from AutoRest |
July 21, 2022
July 21, 2022
Change the schema to use a well-defined type and format.